این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Journal of Research in Medical Sciences، جلد ۱۶، شماره ۱، صفحات ۶۳-۰

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Bispectral index response to cricoid pressure during induction of general anesthesia
چکیده انگلیسی مقاله Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 BACKGROUND: Because the effects of cricoid pressure (CP) on BIS values have not been evaluated, this prospective study was designed to assess the BIS values after application of CP in adult patients during the routine induction of general anesthesia. METHODS: We randomly allocated 70 patients (ASA-I) aged 18-64 years, listed for elective surgery into two groups of cricoid (CP) and non-cricoid (nCP). In the cricoid group, bimanual cricoid pressure was performed after the induction of anesthesia and in the nCP group, simple placement of hands without exerting pressure was performed. Arterial blood pressure, heart rate and BIS were measured and recorded immediately before and after application of cricoid pressure, before laryngoscopy and intubation and then every one minute after intubation until 4 minutes. The data were compared between and within groups using the mixed-design analysis of variance. RESULTS: One minute after application of cricoid pressure and before laryngoscopy, BIS showed significantly higher value compared with the nCP group. Furthermore, one min after intubation, BIS values and arterial blood pressure increased significantly in both groups compared with the baseline values, but the increase in BIS value was more significant in CP group than nCP group. Moreover, BIS values increased significantly 2 minutes after intubation in CP group compared with nCP group. CONCLUSIONS: It was concluded that the application of CP in combination with laryngoscopy and intubation increases the BIS values, which show the inadequacy of anesthesia and hypnosis during the routine induction of anesthesia. KEYWORDS: Laryngoscopy, Intubation, Consciousness Monitors.
کلیدواژه‌های انگلیسی مقاله laryngoscopy, intubation, Bispectral Index

نویسندگان مقاله ریحانک طلاکوب | reihanak talakoub
department of anesthesia and critical care, school of medicine, isfahan university of medical sciences, isfahan

سازمان اصلی تایید شده: دانشگاه علوم پزشکی اصفهان (Isfahan university of medical sciences)

سعید عباسی | saeed abbasi
department of anesthesia and critical care, school of medicine, isfahan university of medical sciences, isfahan

سازمان اصلی تایید شده: دانشگاه علوم پزشکی اصفهان (Isfahan university of medical sciences)

حمید سریزدی | hamid saryazdi
department of anesthesia and critical care, school of medicine, isfahan university of medical sciences, isfahan

سازمان اصلی تایید شده: دانشگاه علوم پزشکی اصفهان (Isfahan university of medical sciences)

بابک jahangirifard | babak jahangirifard
department of anesthesia and critical care, school of medicine, isfahan university of medical sciences, isfahan

سازمان اصلی تایید شده: دانشگاه علوم پزشکی اصفهان (Isfahan university of medical sciences)

مهرداد مسعودی فر | mehrdad masoodifar
department of anesthesia and critical care, school of medicine, isfahan university of medical sciences, isfahan

سازمان اصلی تایید شده: دانشگاه علوم پزشکی اصفهان (Isfahan university of medical sciences)


نشانی اینترنتی http://jrms.mui.ac.ir/index.php/jrms/article/view/5354
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Original Articles
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات