Comparison of ultrasound and optic biometry with respect to eye refractive errors after phacoemulsification
چکیده انگلیسی مقاله
BACKGROUND : Phacoemulsification is one of the best surgical treatments for the cataract. Secondary to the technicaladvances in estimating the intraocular lens (IOL) power, the refractive errors, one of the most important surgical complications after surgery, is now reduced. Currently, two methods of biometry are used to calculate the IOL power, ultrasound biometry and optical biometry. Both methods have their own advantages and it is controversial to use which of them before surgery. We would like to know if there is any difference between these two biometry methods to reduce refractive errors after cataract surgery. METHODS : Present research was a cohort study on the patients undergone phacoemulsification due to cataract in Feiz and Farabi academic hospitals and Aban ophthalmology clinic. We compared eye refractions after cataract surgery in two groups of patients. Ultrasound biometry was done for the first group and the optical biometry for the second one. Mean absolute refractive error (MAE) was compared in the two groups by t test. RESULTS : Eye refractions of 132 patients were studied; 76 patients in group one and 56 patients in group two. The MAE measured 0.67 ± 0.70 diopters for the first group and 0.79 ± 0.76 diopters for the second one and the difference was not significant (P = 0.342). CONCLUSIONS : According to our results the refractive errors after phacoemulsification was the same for both ultrasound and optical biometry methods. The claim of optical biometry, however, to gain a higher precision and thus a significantly better prediction of individual postoperative refraction after cataract surgery is not yet fulfilled. To determine which method is definitely better, more studies are required. KEY WORDS : Cataract, phacoemulsification, biometry, refractive error.
کلیدواژههای انگلیسی مقاله
Cataract, phacoemulsification, biometry, refractive error.
نویسندگان مقاله
حیدرعلی معینی | heidarali moeini
department of ophthalmology, isfahan university of medical science, feiz hospital, isfahan, iran.
سازمان اصلی تایید شده
: دانشگاه اصفهان (Isfahan university)
فاطمه اسلامی | fateme eslami
department of ophthalmology, isfahan university of medical science, feiz hospital, isfahan, iran.
سازمان اصلی تایید شده
: دانشگاه اصفهان (Isfahan university)
اکرم ریسمانچیان | akram rismanchian
department of ophthalmology, isfahan university of medical science, feiz hospital, isfahan, iran.
سازمان اصلی تایید شده
: دانشگاه اصفهان (Isfahan university)
محمدرضا اخلاقی | mohamadreza akhlaghi
department of ophthalmology, isfahan university of medical science, feiz hospital, isfahan, iran.
سازمان اصلی تایید شده
: دانشگاه اصفهان (Isfahan university)
علی najafianjaz | ali najafianjaz
department of ophthalmology, isfahan university of medical science, feiz hospital, isfahan, iran.
سازمان اصلی تایید شده
: دانشگاه اصفهان (Isfahan university)
نشانی اینترنتی
http://jrms.mui.ac.ir/index.php/jrms/article/view/1042
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Articles
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات