این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
جمعه 5 دی 1404
Iranian Journal of Neonatology
، جلد ۷، شماره ۱، صفحات ۴۱-۴۶
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
A Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia
چکیده انگلیسی مقاله
Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of hypoglycemia, admitted to Baqiyatallah Hospital of Tehran, Iran in 2012; the subjects were selected via simple sampling. After obtaining informed consents from the newborns’ parents, 1 cc blood samples were sent to the laboratory for measuring the blood glucose level. Moreover, venous blood samples, as well as heel-stick blood samples, were obtained for glucometer measurements. Blood glucose measurements were used to determine the cut-off value by the receiver operating characteristic (ROC) curve and make comparisons with the diagnostic criteria for hypoglycemia in the literature. Results: A total of 238 infants with the mean weight of 2869±821.9 g were enrolled in this study. The mean (±SD) blood glucose levels were 65.1±22.9, 82.9±24.7, and 84.4±24.8 mg/dl, based on the standard laboratory method, glucometer reading of venous blood samples, and glucometer reading of heel-stick capillary blood samples, respectively. The optimal cut-off point for hypoglycemia was determined as 65 mg/dl, using glucometer-based assessment of heel-stick blood samples. Conclusion: The significant difference in blood glucose levels measured by the laboratory method and outpatient glucometer readings highlights the importance of a cut-off value for rapid assessment and control of blood glucose and timely detection of hypoglycemia. In fact, the cut-off value introduced in the present study could facilitate such measurements.
کلیدواژههای انگلیسی مقاله
Glucometer, Neonatal hypoglycemia, Screening
نویسندگان مقاله
محمد ترکمان | mohammad torkaman
department of pediatrics, faculty of medicine, baqiyatallah university of medical sciences, tehran, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی بقیه الله (Baqiyatallah university of medical sciences)
غلامرضا باقری | gholamreza bagheri
department of pediatrics, faculty of medicine, baqiyatallah university of medical sciences, tehran, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی بقیه الله (Baqiyatallah university of medical sciences)
احمد احمدی | ahmad ahmadi
department of pediatrics, faculty of medicine, baqiyatallah university of medical sciences, tehran, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی بقیه الله (Baqiyatallah university of medical sciences)
امین صبوری | amin saburi
birjand atherosclerosis and coronary artery research center, birjand university of medical sciences, birjand, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی بیرجند (Birjand university of medical sciences)
نشانی اینترنتی
http://ijn.mums.ac.ir/article_6664.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
تحقیقی اصیل
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات