این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Journal of Dental Materials and Techniques، جلد ۳، شماره ۳، صفحات ۹۹-۱۰۵

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Internal and Marginal Fit of Modern Indirect Class II Composite Inlays
چکیده انگلیسی مقاله Introduction: This in vitro study investigates the marginal and internal fit of indirect class II composite restorations. Two different processes for chair-side restorations were compared. In group A, the restorations were fabricated using CAD/CAM technology (Cerec, Sirona, Germany, Bernsheim) and in group B they were made by hand (GrandioSO Inlay System, VOCO GmbH, Germany, Cuxhaven). Methods: For a metal tooth with a MOD cavity each 10 restorations were made for groups A and B. For each restoration, a replica of the cement-gap made from light body silicone was produced by placing the restoration into the cavity of the metal tooth. For this purpose, a special restoration-positioning machine was developed. Each replica was sectioned off in the longitudinal axis (L) and in the cross axis (C). The thickness of the replicas was measured in both directions, using picture analysis software under a light reflection microscope. To evaluate the fit of the restorations, a special fitting parameter was calculated. Statistical analysis was performed with the t test. Results: The fitting-parameter in group B (L: 97.6µm±73.0µm; C: 71.8µm±46.4µm) was significantly lower than that of group A (L: 155.1µm±102.3.0µm; C: 168.2µm±91.9µm) (P< 0,001). Conclusions: Within the limitations of this in-vitro study hand-made composite restorations using the GrandioSO Inlay System seems to be a good alternative to CAD/CAM production. The clinical success of these restorations has to be evaluated in further studies.
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله philipp c pott | philipp c pott
department of prosthetic dentistry and biomedical materials research, hannover medical school, hannover, germany


agnieszka rzasa | agnieszka rzasa
department of prosthetic dentistry and biomedical materials research, hannover medical school, hannover, germany


meike stiesch | meike stiesch
department of prosthetic dentistry and biomedical materials research, hannover medical school, hannover, germany


میکاییل eisenburger | michael eisenburger
department of prosthetic dentistry and biomedical materials research, hannover medical school, hannover, germany



نشانی اینترنتی http://jdmt.mums.ac.ir/article_2967.html
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده 1
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات