عنوان فارسی Torque Removal Evaluation of Screw in One-Piece and Two-Piece Abutments Tightened with a Handheld screwdriver
چکیده فارسی مقاله Introduction: Some clinicians use a handheld screw driver instead of a torque wrench to definitively tighten abutment screws. The aim of this study was to compare the removal torque of one-piece and two-piece abutments tightened with a handheld driver and a torque control ratchet. Methods: 40 ITI implants were placed in acrylic blocks and divided into 4 groups. In groups one and two, 10 ITI one-piece abutments (Solid®) and in groups three and four, 10 ITI two-piece abutments (Synocta®) were placed on the implants. In groups one and three abutments were tightened by 5 experienced males and 5 experienced females using a handheld driver. In groups two and four abutments were tightened using a torque wrench with torque values of 10, 20 and 35 N.cm. Insertion torque and removal torque values of the abutments were measured with a digital torque meter. Results: The insertion torque values (ITVs) of males in both abutments were significantly higher than those of females. ITVs in both Solid® and Synocta® abutments tightened with a handheld screwdriver were similar to the torque of 20 N.cm in the torque wrench. Removal torque values (RTVs) of solid® abutments were higher than those of synocta® abutments. Conclusion: The one- piece abutments (solid®) showed higher RTVs than the two-piece abutments (synocta®). Hand driver does not produce sufficient preload force for the final tightening of the abutment
کلیدواژه‌های فارسی مقاله Hand driver، one-piece abutment، removal torque، torque wrench، two-piece abutment،

عنوان انگلیسی Torque Removal Evaluation of Screw in One-Piece and Two-Piece Abutments Tightened with a Handheld screwdriver
چکیده انگلیسی مقاله Introduction: Some clinicians use a handheld screw driver instead of a torque wrench to definitively tighten abutment screws. The aim of this study was to compare the removal torque of one-piece and two-piece abutments tightened with a handheld driver and a torque control ratchet. Methods: 40 ITI implants were placed in acrylic blocks and divided into 4 groups. In groups one and two, 10 ITI one-piece abutments (Solid®) and in groups three and four, 10 ITI two-piece abutments (Synocta®) were placed on the implants. In groups one and three abutments were tightened by 5 experienced males and 5 experienced females using a handheld driver. In groups two and four abutments were tightened using a torque wrench with torque values of 10, 20 and 35 N.cm. Insertion torque and removal torque values of the abutments were measured with a digital torque meter. Results: The insertion torque values (ITVs) of males in both abutments were significantly higher than those of females. ITVs in both Solid® and Synocta® abutments tightened with a handheld screwdriver were similar to the torque of 20 N.cm in the torque wrench. Removal torque values (RTVs) of solid® abutments were higher than those of synocta® abutments. Conclusion: The one- piece abutments (solid®) showed higher RTVs than the two-piece abutments (synocta®). Hand driver does not produce sufficient preload force for the final tightening of the abutment
کلیدواژه‌های انگلیسی مقاله Hand driver, one-piece abutment, removal torque, torque wrench, two-piece abutment

نویسندگان مقاله جلیل قنبرزاده | jalil ghanbarzadeh
1department of prosthodontics, faculty of dentistry, mashhad university of medical sciences, mashhad, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (Mashhad university of medical sciences)

محبوبه رجب زاده | mahboobeh rajabzadeh
departments of periodontics, school of dentistry, isfahan university of medical sciences,isfahan, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی اصفهان (Isfahan university of medical sciences)

محمدرضا نخعی | mohammadreza nakhaei
dental research center, faculty of dentistry, mashhad university of medical sciences,mashhad, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (Mashhad university of medical sciences)

حمیدرضا rajatihaghi | hamidreza rajatihaghi
dental material research center, faculty of dentistry, mashhad university of medical sciences, mashhad, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (Mashhad university of medical sciences)

نیلوفر طیرانی نجاران | niloufar tayarani najjaran
1department of prosthodontics, faculty of dentistry, mashhad university of medical sciences, mashhad, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی مشهد (Mashhad university of medical sciences)


نشانی اینترنتی http://jdmt.mums.ac.ir/article_2051.html
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده fa
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده 1
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات