این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Journal of Dental Materials and Techniques، جلد ۲، شماره ۴، صفحات ۱۰۹-۱۱۳

عنوان فارسی Effect of Thermocycling on Microleakage of New Adhesive Systems on Primary Teeth: An In-Vitro Study
چکیده فارسی مقاله Introduction: This study investigated the sealing ability of three different adhesives in primary bovine teeth. Methods: Facial and lingual class V cavities were prepared half in enamel and half in cementum, in 48 bovine primary mandibular incisors and randomly divided into three groups and each group divided to two subgroups. The tested adhesives were XPBond (XP), ClearfilS3 Bond (S3), and Xeno III (XE). All cavities were restored with composite and light cured. After 24 hours storage in 37°C distilled water and polishing, teeth were thermocycled and sealed with nail varnish. Then, they were stored in 2% methylene blue and dye penetration was evaluated under a stereomicroscope. Results: No significant differences were recorded in the microleakage value between three adhesives in enamel and dentin margins (p>0.0.5) before and after thermocycling. The lowest microleakage value was obtained in XE followed by XP and S3. Conclusion: There were not any differences between adhesives in enamel and dentin margins of class V cavities on primary bovine teeth.
کلیدواژه‌های فارسی مقاله adhesive system، microleakage، primary teeth، thermocycling،

عنوان انگلیسی Effect of Thermocycling on Microleakage of New Adhesive Systems on Primary Teeth: An In-Vitro Study
چکیده انگلیسی مقاله Introduction: This study investigated the sealing ability of three different adhesives in primary bovine teeth. Methods: Facial and lingual class V cavities were prepared half in enamel and half in cementum, in 48 bovine primary mandibular incisors and randomly divided into three groups and each group divided to two subgroups. The tested adhesives were XPBond (XP), ClearfilS3 Bond (S3), and Xeno III (XE). All cavities were restored with composite and light cured. After 24 hours storage in 37°C distilled water and polishing, teeth were thermocycled and sealed with nail varnish. Then, they were stored in 2% methylene blue and dye penetration was evaluated under a stereomicroscope. Results: No significant differences were recorded in the microleakage value between three adhesives in enamel and dentin margins (p>0.0.5) before and after thermocycling. The lowest microleakage value was obtained in XE followed by XP and S3. Conclusion: There were not any differences between adhesives in enamel and dentin margins of class V cavities on primary bovine teeth.
کلیدواژه‌های انگلیسی مقاله adhesive system, microleakage, primary teeth, thermocycling

نویسندگان مقاله رامین آتش | ramin atash
department of dentistry, université libre de bruxelles, brussels, belgium


امیر شایگان | amir shayegan
department of dentistry, université libre de bruxelles, brussels, belgium


حمیدرضا پوراسلامی | hamidreza poureslami
kerman oral amp; dental research center, department of pediatric dentistry, faculty of dentistry, university of medical sciences, kerman, iran


حمید شریفی | hamid sharifi
department of food hygiene and public health, faculty of veterinary medicine, shahid bahonar university of kerman, iran

سازمان اصلی تایید شده: دانشگاه شهید باهنر (Shahid bahonar university)

نیلوفر شادمان | niloofar shadman
department of restorative dentistry, faculty of dentistry, university of medical science, kerman, iran



نشانی اینترنتی http://jdmt.mums.ac.ir/article_1720.html
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده fa
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده 1
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات