Quality assessment of conventional X-ray diagnostic equipment by measuring X-ray exposure and tube output parameters in Great Khorasan Province, Iran
چکیده انگلیسی مقاله
Introduction: Regular implementation of quality control (QC) program in diagnostic X-ray facilities may affect both image quality and patient radiation dose due to the changes in exposure parameters. Therefore, this study aimed to investigate the status of randomly selected conventional radiographic X-ray devices installed in radiology centers of Great Khorasan Province, Iran, to produce the data needed to formulate QC policies, which are essential to ensure the accuracy of the diagnosis while minimizing the radiation dose. Material and Methods: This cross-sectional study was performed using a calibrated Piranha multi-purpose detector to measure QC parameters in order to unify X‐ray imaging practices using international guidelines. The QC parameters included voltage accuracy, voltage reproducibility, exposure time accuracy, exposure time reproducibility, tube output linearity with time andmilliampere (mA), and tube output reproducibility. Data analysis procedures were performed based on the type of an X-ray generator, which has not been reported in previous studies. Results: The results showed that the implementation of high-frequency X-ray generators were more advantageous compared to alternative current generators, due to their efficient, better accuracy, linearity, and reproducibility. Conclusion: The survey revealed that the QC program was not conducted at regular intervals in some of the investigated radiology centers, mostly because of inadequate enforcement by national regulatory authorities for implementation of QC program.
کلیدواژههای انگلیسی مقاله
Diagnostic Equipment, Quality Control, Radiography
نویسندگان مقاله
| Mohammad Hashemi
Medical Physics Research Center, Mashhad University of Medical Sciences, Mashahd, Iran.
| Shahram Bayani Roodi
Medical Physics Research Center, Mashhad University of Medical Sciences, Mashahd, Iran.
| Fateme Shahedi
Department of Radiology, School of Paramedical Sciences, Torbat Heydariyeh University of Medical Sciences, Torbat Heydariyeh, Iran.
| Mahdi Momennezhad
Medical Physics Research Center, Mashhad University of Medical Sciences, Mashahd, Iran.
| Hoda Zare
Medical Physics Research Center, Mashhad University of Medical Sciences, Mashahd, Iran.
| Hamid Gholamhosseinian
Medical Physics Research Center, Mashhad University of Medical Sciences, Mashahd, Iran.
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_11746.html
فایل مقاله
اشکال در دسترسی به فایل - ./files/site1/rds_journals/145/article-145-1136101.pdf
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Paper
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات