این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
یکشنبه 30 آذر 1404
The Archives of Bone and Joint Surgery
، جلد ۳، شماره ۴، صفحات ۲۴۴-۲۴۹
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Correlation of Reconstructed Scaphoid Morphology with Clinical Outcomes
چکیده انگلیسی مقاله
Background: Scaphoid mal::union:: alters the carpal kinematics and impairs clinical outcome because of pain, weakness, restricted range of motion and predisposing the wrist joint to early osteoarthritis. The aim of this study was to evaluate the influence of the scaphoid morphological angles on clinical outcomes in patients with reconstructed scaphoid by non-vascularized bone graft. Methods: Seventeen male patients with the mean age of 31.7±3.7 years and mean non-::union:: time of 31.5±14.7 months were enrolled in this retrospective study. Average follow up was 48.8±9.4 months. At the last follow-up, the patients were evaluated clinically for pain, wrist range of motion, grip strength, and wrist functional status. They were also evaluated radiologically by wrist radiographs and computerized tomography (CT). The overall clinical outcomes were evaluated by the Cooney wrist function score. The morphology of the reconstructed scaphoids was evaluated by the lateral intrascaphoid angle, antroposterior intrascaphoid angle, dorsal cortical angle, measuring the length (mm), and height-to-length ratio on CT scan. The radiological measurements were compared against the overall clinical outcomes. Results: There were 7 excellent, 7 good, 3 fair clinical results. The mean Cooney wrist function score was 83±4. The mean lateral intrascaphoid angle was 34.8±1.4 degrees, mean antroposterior intrascaphoid angle was 33.4±2.2 degrees, mean dorsal cortical angle was 158.3±4.8 degrees, mean scaphoid length was 22.1± 0.7 mm, and mean scaphoid height-to-length ratio was 0.74±0.04. There were no significant statistical correlations between the lateral intrascaphoid angles, antroposterior intrascaphoid angles, dorsal cortical angles, scaphoid lengths and scaphoid height-to-length ratios and Cooney wrist scores in the patients. Conclusion: In the current study, all the patients had some degree of scaphoid mal::union::; however, the radiological measurements of the reconstructed scaphoids did not correlate with the clinical outcomes.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
احمدرضا افشار | ahmadreza afshar
department of orthopedics, urmia university of medical sciences, urmia, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی ارومیه (Urmia university of medical sciences)
افشین محمدی | afshin mohammadi
department of radiology, urmia university of medical sciences, urmia, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی ارومیه (Urmia university of medical sciences)
کیان ظهرابی | kian zohrabi
department of orthopedics, urmia university of medical sciences, urmia, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی ارومیه (Urmia university of medical sciences)
نسرین نوایی فر | nasrin navaeifar
department of orthopedics, urmia university of medical sciences, urmia, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی ارومیه (Urmia university of medical sciences)
سام سامی | sam sami
department of orthopedics, shafa yahyaian hospital, iran university of medical sciences, tehran, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی ایران (Iran university of medical sciences)
حسن طالب | hassan taleb
department of orthopedics, urmia university of medical sciences, urmia, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی ارومیه (Urmia university of medical sciences)
نشانی اینترنتی
http://abjs.mums.ac.ir/article_4712.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
RESEARCH PAPER
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات