این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
یکشنبه 23 آذر 1404
The Archives of Bone and Joint Surgery
، جلد ۷، شماره ۲، صفحات ۱۰۵-۱۱۱
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Precontoured Locking Plate Treatment in Mid-Shaft Clavicle Fractures: Outcomes and Complications with a Minimun of 2- Years Follow up
چکیده انگلیسی مقاله
Background: The aim of this study was to evaluate functional outcome and complications with a long term followup (minimum of 2 years post-operative) in patients with mid-shaft clavicle fractures treated with precontoured lockingplates.Methods: We included 41 patients. Goniometric measurement of shoulder range of motion (ROM) was performed,as well as functional evaluation using the rating scale shoulder of the University of California (UCLA), the Constantscale, score of disability of the arm, shoulder and hand (DASH) and visual analog scale (VAS). Postoperativecomplications, implants removal rates and new x-rays were analized.Results: The mean postoperative follow-up was 41.5 (24; 69. SD 13.4) months. Mean shoulder anterior elevationwas 168.5º (120; 180. SD 22.9). The average value obtained for abduction was 175.2° (150; 180. SD 27.8), as tointernal and external rotations, these were not affected. DASH 1.27% (0%; 25%. SD 4.3), UCLA 33.6 points (20;35. SD 3.5), Constant 90.5 points (50; 100. SD 11.2) and VAS was 0 in 34 patients (83%). Complications: mildresidual pain (3), hypoesthesia of the infraclavicular area (2), and rupture (1) and loosening (1) of the implant.hardware removal due to intolerance (2 cases) and new osteosynthesis due to acute implant rupture (1 case).Conclusion: Our experience after a mean follow-up of 41.5 months with precontoured locking plates for the treatmentof displaced mid-shaft clavicle fractures has shown good functional results, with low complication and reoperationrate.Level of evidence: IV
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
| J. M. Patino
Upper Extremity Unit Orthopedics and Traumatology Department, Hospital Militar Central, Cosme Argerich, Buenos Aires, Argentina
| A. F. Rullan Corna
Upper Extremity Unit Orthopedics and Traumatology Department, Hospital Militar Central, Cosme Argerich, Buenos Aires, Argentina
| A. E. Michelini
Upper Extremity Unit Orthopedics and Traumatology Department, Hospital Militar Central, Cosme Argerich, Buenos Aires, Argentina
| I. Abdon
Upper Extremity Unit Orthopedics and Traumatology Department, Hospital Militar Central, Cosme Argerich, Buenos Aires, Argentina
| S. D. Hochbaum
Upper Extremity Unit Orthopedics and Traumatology Department, Hospital Militar Central, Cosme Argerich, Buenos Aires, Argentina
| F. Zicovich Wilson
Upper Extremity Unit Orthopedics and Traumatology Department, Hospital Militar Central, Cosme Argerich, Buenos Aires, Argentina
نشانی اینترنتی
http://abjs.mums.ac.ir/article_10828.html
فایل مقاله
اشکال در دسترسی به فایل - ./files/site1/rds_journals/328/article-328-1285405.pdf
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
RESEARCH PAPER
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات