عنوان انگلیسی A Unified Framework for Delineation of Ambulatory Holter ECG Events via Analysis of a Multiple-Order Derivative Wavelet-Based Measure
چکیده انگلیسی مقاله In this study, a new long-duration holter electrocardiogram (ECG) major events detection-delineation algorithm is described which operates based on the false-alarm error bounded segmentation of a decision statistic with simple mathematical origin. To meet this end, first three-lead holter data is pre-processed by implementation of an appropriate bandpass finite-duration impulse response (FIR) filter and also by calculation of the Euclidean norm between corresponding samples of three leads. Then, a trous discrete wavelet transform (DWT) is applied to the resulted norm and an unscented synthetic measure is calculated between some obtained dyadic scales to magnify the effects of low-power waves such as P or T-waves during occurrence of arrhythmia(s). Afterwards, a uniform length window is slid sample to sample on the synthetic scale and in each slid, six features namely as summation of the nonlinearly amplified Hilbert transform, summation of absolute first order differentiation, summation of absolute second order differentiation, curve length, area and variance of the excerpted segment are calculated. Then all feature trends are normalized and superimposed to yield the newly defined multiple-order derivative wavelet based measure (MDWM) for the detection and delineation of ECG events. In the next step, a α-level Neyman-Pearson classifier (which is a false-alarm probability-FAP controlled tester) is implemented to detect and delineate QRS complexes. To show advantages of the presented method, it is applied to MIT-BIH Arrhythmia Database, QT Database, and T-Wave Alternans Database and as a result, the average values of sensitivity and positive predictivity Se = 99.96% and P+ = 99.96% are obtained for the detection of QRS complexes, with the average maximum delineation error of 5.7 msec, 3.8 msec and 6.1 msec for P-wave, QRS complex and T-wave, respectively showing marginal improvement of detection-delineation performance. In the next step, the proposed method is applied to DAY hospital high resolution holter data (more than 1,500,000 beats including Bundle Branch Blocks-BBB, Premature Ventricular Complex-PVC and Premature Atrial Complex-PAC) and average values of Se=99.98% and P+=99.97% are obtained for QRS detection. In summary, marginal performance improvement of ECG events detection-delineation process in a widespread values of signal to noise ratio (SNR), reliable robustness against strong noise, artifacts and probable severe arrhythmia(s) of high resolution holter data and the processing speed 163,000 samples/sec can be mentioned as important merits and capabilities of the proposed algorithm.
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله محمدرضا همایی نژاد | m r homaeinezhad


a غفاری | a. ghaffari


h نجاران طوسی | h najjaran toosi


m طهماسبی | m. tahmasebi


محمد مهدی daevaeiha | m m daevaeiha



نشانی اینترنتی http://ijeee.iust.ac.ir/browse.php?a_code=A-10-32-4&slc_lang=en&sid=en
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده 4-Biomedical Signal Processing
نوع مقاله منتشر شده Research Paper
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات