این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Archives of Hygiene Sciences، جلد ۵، شماره ۲، صفحات ۱۰۲-۱۱۰

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Assessment of a Continuous Electrocoagulation on Turbidity Removal from Spent Filter Backwash Water
چکیده انگلیسی مقاله Background & Aims of the Study: Spent filter backwash water (SFBW) consists of 1-5% of the total treated water typically and it has a high turbidity. Because of the scarcity of water resources and in order to prevent the environmental contamination, effluent treatment of rapid sand filter backwashing is unavoidable. One of the new technologies for removal of turbidity from the effluent is ElectroCoagulation (EC) processes. This study aimed to examine the efficiency of continuous electrocoagulation in turbidity removal from spent filter backwash water. Materials & Methods: This study was non-continuous experiment. A rectangular cube electrocoagulation tank in 24 cm×17 cm×18 cm dimensions from Plexiglas with the volume of 7.35 liter was made. In this tank there were 4 metal plates (electrode) (15× 22× 0.1cm); two electrodes as cathode and anode which were made of aluminum and iron, respectively. All of the tests were done in continuous flow. According to the study criteria (Time, Turbidity and pH), 126 sample got with the turbidity 320, 350, 400 NTU from rapid sand filter backwashing water, so they were tested in current density; 1, 1.4, 1.8, 2, 2.4, 2.8 and 3.2 ampere in 3 selected detention times (10, 20 and 30 min). Each experiment was repeated two times. In this research the space of electrode and pH is fixed at 1.5 cm and 8.2. Results: In this case the highest turbidity removal for Al electrode from rapid sand filter backwashing occurred in the current density 3.2 ampere, 30 min detention time and 320 NTU turbidity. The percent of removal for Al was 95.12. The highest removal for Fe electrode from rapid sand filter backwashing occur in the current density 3.2 ampere, 30 min detention time and 320 NTU turbidity. The percent of removal for Fe was 87.40. Conclusion: Regarding to the results of the tests, using electrocoagulation has an appropriate efficiency in turbidity removal.
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله حسین جعفری منصوریان | hossein jafari mansoorian
environmental health engineering research center, department of environmental health, kerman university of medical scien


محسن انصاری | mohsen ansari
environmental science and technology research center, department of environmental health engineering, shahid sadoughi university of medical science, yazd, iran


احسان احمدی | ehsan ahmadi
department of environmental health engineering, health school, tehran university of medical sciences, tehran, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی تهران (Tehran university of medical sciences)

غریب مجیدی | gharib majidi
department of environmental health engineering, health school, qom university of medical sciences, qom, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی قم (Qom university of medical sciences)


نشانی اینترنتی http://jhygiene.muq.ac.ir/browse.php?a_code=A-10-52-1&slc_lang=en&sid=en
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده 1
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات