این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
سه شنبه 25 آذر 1404
Iranian Heart Journal
، جلد ۱۷، شماره ۳، صفحات ۲۷-۳۵
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Measuring and Modeling the Viscoelastic Properties of the Human Saphenous Vein Using the Pressure–Diameter Test
چکیده انگلیسی مقاله
Coronary artery bypass graft surgery is a customary therapy for vascular-related diseases, with many thousands of such a surgical modality reported annually. In this surgery, the saphenous vein, internal mammary artery, or radial artery is grafted in order to replace the coronary arteries. Using a device designed in our own laboratory, we primarily sought to find a suitable model representing the mechanical behavior of the human saphenous vein wall and then to assess its mechanical properties. The most important feature of this device is its ability to simulate the physiological conditions that exist inside the human body. We obtained 2 samples the saphenous opening and the medial epicondyle in patients with hypertension. After performing measurements at frequencies near to the heart beat frequency and finding the loss and storage moduli for each frequency, we found that-in the scanned frequency range-the Kelvin model was the best approach to evaluating the viscoelastic behavior of the vessels. Our findings also indicated that the elasticity and damping coefficients could be deemed equal along the length of the saphenous vein. Accordingly, we would advise that heart surgeons not consider the changes in the mechanical properties along the length of the saphenous vein at the time of transplantation. (Iranian Heart Journal 2016; 17(3):27-35
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
Morteza Darjani |
Department of Biomedical Engineering, Science and Research Branch, Islamic Azad University, Tehran, I.R. Iran.
Ali Esteki |
Department of Biomedical Engineering and Physics, Shahid Beheshti University of Medical Sciences, Tehran, I.R.Iran.
Ahmad Hassantash |
Modares Hospital, Institute of Cardiovascular Research, Shahid Beheshti University of Medical Sciences, Tehran, I.R. Iran.
نشانی اینترنتی
http://journal.iha.org.ir/article_83149_0c5c9da12bb0c046cfb950b0bc94d44c.pdf
فایل مقاله
اشکال در دسترسی به فایل - ./files/site1/rds_journals/162/article-162-1423923.pdf
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات