این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
دوشنبه 17 آذر 1404
International Journal of Radiation Research
، جلد ۱۷، شماره ۲، صفحات ۲۰۹-۲۱۶
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Low kilovolt “prospective ECG-triggering” vs. “retrospective ECG-gating” coronary CTA: comparison of image quality and radiation dose
چکیده انگلیسی مقاله
Background: To compare image quality and radiation doses of low kilovolt (kV) "prospective ECG-triggering" (PT) and standard "retrospective ECG-gating" (RG) coronary computed tomography (CT) angiography. Materials and Methods: A total of 101 consecutive patients (76 males, 25 females; mean age: 55.44 ± 8.28 years) with low-to-intermediate risk status for coronary artery disease and with a body mass index (BMI) of < 30 kg/m² were prospectively included in the study. The images were acquired with a 64-detector (128-slice) CT using the tube current modulation technique. The PT CT technique (100 kV, heart rate [HR]< 70) was applied in 59 patients, while the RG CT technique (120 kV, HR≥70-90) was applied in 42 patients. The study was approved by the ethics committee. All patients provided informed written consent. Results: No significant difference was found between age, sex and BMI of both groups (p > 0.05). The mean image quality score was 2.87 ± 0.25 for the low kV PT CT technique and 2.73 ± 0.31 for the RG CT technique, which was statistically significant (p < 0.05). No statistically significant difference was found between groups for signal-noise and contrast-noise ratios (p > 0.05). The mean effective dose was 1.43 ± 0.3 mSv for low kV PT CT technique and 8.20±2.36 mSv for the RG CT technique (p < 0.001). Conclusion: In the low kV PT CT technique, the radiation dose is significantly reduced without loss of image quality. This technique can reliably be used in patients with BMI< 30 kg/m² and HR less than 70 bpm.
کلیدواژههای انگلیسی مقاله
Prospective ECG-triggering, kilovolt, coronary CTA.
نویسندگان مقاله
| G. Gokalp
Department of Radiology, Uludag University Medical Faculty, Gorukle, Bursa, Turkey
نشانی اینترنتی
http://ijrr.com/browse.php?a_code=A-10-1-775&slc_lang=en&sid=1
فایل مقاله
اشکال در دسترسی به فایل - ./files/site1/rds_journals/42/article-42-1439175.pdf
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
Radiation Biology
نوع مقاله منتشر شده
تحقیق بدیع
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات