این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
جمعه 28 آذر 1404
Iranian Journal of Medical Physics
، جلد ۱۵، شماره Special Issue-۱۲th. Iranian Congress of Medical Physics، صفحات ۶-۶
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Designing and developing an in-house CCD based optical CT scanner for gel dosimetry
چکیده انگلیسی مقاله
Introduction: Measurement of the complex 3D radiation dose distribution created with advanced radiotherapy techniques such as IMRT and SRS became very important. Polymer gel dosimetry (PGD) is proposed method to recording this dose distribution. MRI, X-ray CT, ultrasound, spectrophotometry and optical CT scanners can be used for readout of Polymer gel dosimeters. Although MRI is gold standard readout instrument, but it is costly and time- consuming. Optical CT is faster and has very lower cost than other methods. The aim of this work is designing and developing an in-house fast CCD based optical computed tomography scanner to extract the 3D radiation dose distribution that recorded in irradiated PGDs. Materials and Methods: in this work we used an array of high power LEDs by 650nm wave length as broad beam light source and a CCD camera as large area detector. The image projections of test object that immersed in a water tank and its rotational movement were controlled by a stepper motor was obtained. Image reconstruction carried out in MATLAB environment with the Filtered back projection method. Results: Reconstructed image quality is very promising. And it is comparable to results of the other works. Contrast to Noise Ratio (CNR) of reconstructed images without any filters in the back projection algorithm was 0.41. Using ramp filter with 0.2 cutoff frequency, gained a 1.1 in CNR and using Butterworth filter with cutoff frequency of 0.3 gained a CNR of 1.3. Increasing cutoff frequency for Butterworth filter will degrade noise properties of reconstructed image and CNR goes down to 0.82, which is comparable with similar works. Conclusion: Optical CT readout system is considered one of the best options for gel readings. If we can overcome the problems of reconstructed images with light rays, this system can be useful for fast and accurate readout of irradiated polymer gel dosimeters.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
| Mahmoud Shiri
Medical Physics and Biomedical Engineering Dept., Shahid Beheshti University of Medical sciences, Tehran, Iran
| Ahmad Mostaar
Medical Physics and Biomedical Engineering Dept., Shahid Beheshti University of Medical sciences, Tehran, Iran
| Zahra Mansouri
Medical Physics and Biomedical Engineering Dept., Shahid Beheshti University of Medical sciences, Tehran, Iran
| Seyed Mohsen Sadat-Shahabi
Medical Physics and Biomedical Engineering Dept., Shahid Beheshti University of Medical sciences, Tehran, Iran
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_11848.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Conference Proceedings
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات