این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
جمعه 28 آذر 1404
Iranian Journal of Medical Physics
، جلد ۱۵، شماره Special Issue-۱۲th. Iranian Congress of Medical Physics، صفحات ۷-۷
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Radiation dose of Pediatrics in a general hospital in comparison to a pediatrics hospital
چکیده انگلیسی مقاله
Introduction: Increasing CT scan application increased the cancer risk in pediatrics in recent decays. Imaging centers approach for diagnosis of disease cause to different radiation dose to patients. Because of rapid pediatrics body growth, the most important challenge to determining the radiation dose is wide variations of size in different ages. Thus, we used Size- specific dose estimates (SSDE) to achievement more accurate radiation dose assessment. In this study the radiation dose of head examinations of a general hospital (Trauma center of western Iran) is compared to a pediatrics hospital to find which one has a better approach for dose management. Materials and Methods: We evaluated the total number of 280 CT scans in four age groups (≤1, 2-5, 6-10, 11-15 years. Number of 35 CT scans selected for every age group in both hospitals, separately. Volume Computed Tomography Dose Index (CTDIV), Dose Length Product (DLP), default phantom (16 or 32 cm) and age were recorded in prepared sheets using PACS viewer. Water equivalent diameter (DW) and SSDE calculated using the AAPM TG-220. Third and first quartile and mean ± SD were acquired using SPSS (SPSS Inc., Chicago, IL). Results: Third quartile of SSDE was 19.64, 18.70, 18.49 and 18.13 mGy in general hospital; 13.78, 11.92, 11.94 and 20.77 mGy for pediatrics hospital in age groups of ≤1, 2-5, 6-10, 11- 15 years respectively. Third quartile of DLP was 317.4, 344.7, 344.7 and 344.6 mGy in general hospital; 128.5, 136.5, 152.5 and 250.8 mGy for pediatrics hospital in age groups of ≤1, 2-5, 6-10, 11-15 years respectively. Third quartile of CTDIV was 18.3 mGy for all age categories in general hospital; 11.5, 11.5, 11.5, and 21.1mGy for pediatrics hospital in age groups of ≤1, 2-5, 6-10, 11-15 years respectively. Conclusion: General hospital gives the higher radiation dose to pediatrics for head scans with the exception of 11-15 years' group. Optimizing the protocols according to the patient size is essential in both hospitals. Finally, pediatric hospital has a better dose management for pediatrics CT scans.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
| Ahmad Mohammadbeigi
MSc Student of Medical Physics, Students Research Committee, School of Medicine, Kermanshah University of Medical Sciences, Kermanshah, Iran.
| Karim Khoshgard
Department of Medical Physics, School of Medicine, Kermanshah University of Medical Sciences, Kermanshah, Iran.
| Abbas Haghparast
Department of Medical Physics, School of Medicine, Kermanshah University of Medical Sciences, Kermanshah, Iran.
| Mohammad Taghi Eivazi
Department of Medical Physics, School of Medicine, Kermanshah University of Medical Sciences, Kermanshah, Iran.
| Masoud Rezaei
Medical Physics Research Center, Department of Medical Physics, Mashhad University of Medical Sciences, Mashhad, Iran.
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_11850.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Conference Proceedings
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات