این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
پنجشنبه 27 آذر 1404
Iranian Journal of Medical Physics
، جلد ۱۵، شماره Special Issue-۱۲th. Iranian Congress of Medical Physics، صفحات ۱۹-۱۹
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Dosimetric comparison of conventional and field-in-field techniques in early stage breast cancer radiotherapy
چکیده انگلیسی مقاله
Introduction: Breast conserving surgery followed by adjuvant radiotherapy (RT) of the whole breast is accepted as the treatment of choice in early stage breast cancer. Due to breast irregularities, it is difficult to access homogenous dose distribution with conventional techniques. Currently, it is possible to use varied breast irradiation techniques, such as field- in-field (FIF), to apply a more homogenous distribution of doses within target volumes, and organs at risk (OAR) sparing which lead to achieve better treatment outcome. This study aimed to compare conventional and FIF techniques dosimetrically Materials and Methods: Twenty patients with early-stage breast cancer underwent computed tomography (CT) with a 16 Slice CT simulator; datasets were transferred to the treatment planning system (TPS) via a digital imaging communications in medicine (DICOM). Two different treatment plans were created for each patient by the same medical physicist: a wedge base (conventional) plan and a FIF plan. Then, dosimetric and monitor unit (MU) results were compared. Results: Dosimetric indices in the planning target volume (PTV) were more satisfying with the FIF technique than with three dimensional-conformal RT (3D-CRT). FIF reduced the maximum doses of PTV and MU. In addition, the FIF technique reduced doses to the heart (in left-side irradiation cases) and ipsilateral lung by 7% and 8%, respectively. FIF also significantly reduced V40 (volume receiving 40 Gy) of heart in left side breast irradiation. V20 of lung (volume receiving 20 Gy), and also doses to the contralateral lung did not differ significantly. Conclusion: FIF can produce more homogenous doses within the PTV, and reduce doses to the OAR. Moreover, by using the FIF technique in breast irradiation, MUs required for therapy are significantly decreased compared with that required by 3D-CRT.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
| Seyed Mohammad Hosseini
Department of Medical Physics, Faculty of Medicine, Mashhad University of medical sciences, Mashhad, Iran Medical physics Research Center, Faculty of Medicine, Mashhad University of medical sciences, Mashhad, Iran
| Mahdi Momennezhad
Department of Medical Physics, Faculty of Medicine, Mashhad University of medical sciences, Mashhad, Iran Medical physics Research Center, Faculty of Medicine, Mashhad University of medical sciences, Mashhad, Iran Department of Radiotherapy and Oncology, Imam Reza Hospital, Mashhad, Iran
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_11864.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Conference Proceedings
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات