این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
جمعه 28 آذر 1404
Iranian Journal of Medical Physics
، جلد ۱۵، شماره Special Issue-۱۲th. Iranian Congress of Medical Physics، صفحات ۲۴-۲۴
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Evaluation of dose distribution and dose gradient in brachytherapy cylindrical applicators using a dedicated Phantom for Iridium-192 and Cobalt-60 HDR sources
چکیده انگلیسی مقاله
Introduction: A study was performed to evaluate radiation dose distribution and dose gradient around cylindrical applicators for high-dose-rate (HDR) brachytherapy systems with 192Ir, 60Co brachytherapy source applied for rectal and vaginal cancers treatments. Materials and Methods: Two additional computed tomography (CT) based plans were generated using a dedicated Phantom for both 60Co source and 192IridumHDR sources. The phantom contains a film and TLD-100 position on the top and peripheral areas, and a rectum cylinder with 1.5 cm insert caps into the phantom. Dose coverage of 5-mm shell surrounding the cylinder, was then evaluated for both scenarios. Results:A significant dose reduction from the expectation dose for 192Ir at the central points of the cylinder tip was observed. The results were then verified by measurements through radio- chromic film and TLDs. Conclusion: Both 60Co and 192Ir sources were found to be suitable HDR sources for vaginal treatment using a cylindrical applicator with advantages of reducing radiation exposure to Organ At Risks (OARs) in the lower dose range, and appropriate prescribed dose to the target
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
| Mohammad Hadi Gholami
Islamic Azad University, Science and research branch, Tehran, Iran Mahdieh Radiotherapy and Oncology charity center, Hamadan, Iran
| Mohammad Mohammadi
Department of Medical Physics, Royal Adelaide Hospital, Adelaide, SA 5000 AUSTRALIA. School of Physical Sciences, the University of Adelaide, SA 5005 AUSTRALIA. Department of Medical Physics, Reza Radiotherapy and Oncology Center, Mashhad, Iran
| Abdolazim Sedighi
Department of radiation oncology, University of medical science, Hamedan, Iran
| Ramin Jaberi
Department of Radiation Oncology, Tehran University of Medical Sciences, Tehran, Iran
| Fahimeh Rezaei
MSc of Medical physics, Department of Medical physics, Kermanshah University of Medical sciences, Kermanshah, Iran
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_11879.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Conference Proceedings
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات