این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
پنجشنبه 27 آذر 1404
Iranian Journal of Medical Physics
، جلد ۱۵، شماره Special Issue-۱۲th. Iranian Congress of Medical Physics، صفحات ۳۱-۳۱
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Generating the synthetic CT (sCT) and synthetic MR (sMR: sT1w/sT2w) images of the brain using atlas based method
چکیده انگلیسی مقاله
Introduction: Radiation therapy planning (RTP) is one of the clinical applications in which both CT scan and MRI are used. MR and CT images are applied to determine the target volume and calculation of dose distribution, respectively. In addition, using two imaging modalities increases the department workload and cost. In this study, an algorithm was presented to create synthetic CT (sCT) and synthetic MR (sMR: sT1w/sT2w) images consequently CT or MR images are not taken from patient. Materials and Methods: The synthetic CT (sCT) and synthetic MR (sMR: sT1w/sT2w) images was generated by atlas based method. The dataset consisted of MR and CT paired images from 17 brain RT patients. To generate sCT/sMR image, first each MR/CT atlas was registered to the MR/CT target image, the resulting transformation was applied to the corresponding CT/MR atlas which created the set of deformed images. Then, deformed images were fused to generate a single sCT/sMR. The sCT/sMR was compared with the real CT/MR images using the MAE. Results: The evaluations performed by MAE showed a good agreement between the sCT/sMR and real CT/MR images. The results represented 72±11.3 HU, 51±7.3 image intensity and 64±7.3 image intensity for sCT, sT1w and sT2w, respectively. Conclusion: This method showed that sT1w images have lesser MAE with respect sT2w. As a result, CT in transferring the brain tissues geometry to sT1w is more successful than sT2w. Also, the sCT images based T1w are in better agreement with real CT than sCT images based T2w.
کلیدواژههای انگلیسی مقاله
Synthetic CT, CT, Synthetic MR, MRI Radiotherapy
نویسندگان مقاله
| Fariba Farhadi Birgani
Department of Medical Physics, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| Mohamad Javad Tahmasebi Birgani
Radiation Therapy and Medical Physics Department, Golestan Hospital, Jundishapur University of Medical Sciences, Ahvaz, Iran
| Fatemeh Maghsoodinia
Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran.
| Roghayeh Kamran Samani
Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_11886.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Conference Proceedings
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات