این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
پنجشنبه 27 آذر 1404
Iranian Journal of Medical Physics
، جلد ۱۵، شماره Special Issue-۱۲th. Iranian Congress of Medical Physics، صفحات ۳۵-۳۵
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Evaluation of methods of co-segmentation on PET/CT images of lung tumor: simulation study
چکیده انگلیسی مقاله
Introduction: Lung cancer is one of the most common causes of cancer-related deaths worldwide. Nowadays PET/CT plays an essential role in radiotherapy planning specially for lung tumors as it provides anatomical and functional information simultaneously that is effective in accurate tumor delineation. The optimal segmentation method has not been introduced yet, however several methods have been proposed up to now. Lake of suitable gold standard for correct evaluating of segmentation algorithms is the most important reason of it. The Monte-Carlo simulations are the ideal tool since it allows a complete description of data not accessible in the case of patient studies. The aim of this study was to simulate clinically realistic Monte-Carlo PET/CT data, obtained using the NCAT numerical phantom and the GATE simulation tool, to compare precision of 3 co- segmentation algorithms on lesion delineation. Materials and Methods: In this study, detection system and geometry of PET/CT scanner were modeled using GATE simulation toolkit. After validation of simulated scanner and modification of GATE parameters, a digital phantom was designed using NCAT digital phantom based on patient's information extracted from PET/CT images. Then 5 sphere-shape tumors with different sizes were created in lung as lesions. In order to implement co-segmentation algorithms, simulated images of phantoms were merged with CT images by AMIDE (a Medical Image Data Examiner). Finally simulated pulmonary lesions were segmented using 3 co-segmentation matlab codes: Watershed, Region growing and Graph cut. Comparing of these methods was performed by parameters included: Tumor Diameter (TD) and Gross Tumor Volume (TV). At the end, results of PET segmentation and PET/CT segmentation were compared as well in order to evaluate effect of using CT information in precision of tumor volume detection. Results: TD and GTV measured from PET/CT images segmented by region growing had difference less than 5% from gold standard and this method was efficient for all 5 tumor sizes. Graph cut outcomes had GTV and TD difference less than 15 % and it could not detect tumors with size less than 3 cm. watershed did not have correct outcomes. The co-segmented tumor volume on PET-CT image was most strongly correlated with specified tumor volume of phantoms compared with co-segmented tumor volume on PET individually. Conclusion: Results demonstrate that among 3 segmentation algorithm, region growing had the most accurate outcomes and watershed was the weakest method. It also showed accuracy of segmentation methods was depended on tumor size especially for graph cut. Tumors of less than 3 cm were indistinguishable by graph cut method and watershed was an incapable algorithm for tumor delineation. Accuracy on GTV and TD measurement using all 3 segmentation methods was largely improved on PET/CT fused image compared to PET image individually as anatomical information of CT.
کلیدواژههای انگلیسی مقاله
Monte Carlo Simulation, Co- Segmentation, PET/CT, NCAT
نویسندگان مقاله
| Elham Kashian
MSc student of Biomedical Engineering, Department of Biomedical Engineering, University of Medical Sciences, Kermanshah, Iran
| Hadi Taleshi Ahangari
Assistant professor, Department of Medical Physics, University of Medical Sciences, Semnan, Iran
| Vahab Dehlaghi
Associate Professor, Department of Biomedical Engineering, University of Medical Sciences, Kermanshah, Iran
| Karim Khoshgard
Assistant professor, Department of Medical Physics, University of Medical Sciences, Kermanshah, Iran
| Pardis Ghafarian
Assistant professor, Shahid beheshti University of Medical Sciences, Tehran, Iran Clinical physicist, Masih Daneshvari Hospital, Tehran, Iran
| Hossein Mousavie Anijdan
Assistant professor, Department of Medical Physics, University of Medical Sciences, babol, Iran
| Shiva Zarifi
MSc student of Medical Physics, Department of Medical Physics, University of Medical Sciences, Semnan, Iran
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_11929.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Conference Proceedings
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات