این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Iranian Journal of Medical Physics، جلد ۱۵، شماره Special Issue-۱۲th. Iranian Congress of Medical Physics، صفحات ۴۴-۴۴

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Breast Radiation Protection in Coronary Angiography
چکیده انگلیسی مقاله Introduction: Coronary angiography (CA) is an interventional diagnostic procedure to assess cardiovascular disease. CA is performed using dedicated fluoroscopic systems equipped with either flat detector or image intensifier. There is an increase in the number of CA annually. Reducing the radiation exposure in the CA is essential, especially due to high fluoroscopy time. In order to breast radiation protection in coronary angiography, the use of bismuth composite shield is a selective method. The purpose of this study was to evaluate the effectiveness of new bismuth composite shield to reduce the amount of received dose to the breast in coronary angiography. Method and Materials: The standard female phantom and Siemens angiography system used in this research. All the procedures were carried out by one operator because factors such as the operator's skill and experience may affect on the patient radiation exposure. The bismuth composite shields were placed on the foam with thickness of 1 cm, exactly on the back of the phantom. Dose measurements were conducted by using three thermo luminescence dosimeters (TLDs) over each breasts location with and without using bismuth shield. Results: Breast dose was 2.45 mSv without using shield. After applying the bismuth composite shields, the recorded dose was changed to between 2.15 to 2.22 mSv. Therefore, the use of shields causes 10 % - 12% dose decline of sensitive breast tissue with acceptable imaging. Conclusion: The results showed that the use of bismuth composite shields in the coronary angiography, leads to an acceptable decrease in breast received dose.
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله | Reza Malekzadeh
Medical Radiation Sciences Research Team, Tabriz University of Medical Sciences, Tabriz, Iran Student research committee, Tabriz University of Medical Sciences, Tabriz, Iran


| Parinaz Mehnati
Department of Medical Physics, School of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran


| Mohammad Yousefi Sooteh
Department of Medical Physics, School of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran


| Ali Tarighatnia
Department of Medical Physics, School of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran


| Yagub Khalegi Fard
Tabriz Valiasr Hospital, Radiology and CT Scan Department, Tabriz, Iran



نشانی اینترنتی http://ijmp.mums.ac.ir/article_11945.html
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Conference Proceedings
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات