این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
پنجشنبه 27 آذر 1404
Iranian Journal of Medical Physics
، جلد ۱۵، شماره Special Issue-۱۲th. Iranian Congress of Medical Physics، صفحات ۷۱-۷۱
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Measuring the Skyshine from Linear accelerator in Rajaee Oncology Hospital
چکیده انگلیسی مقاله
Introduction: Radiation therapy is using the ionizing radiation to eliminate or minimize cancerous tissues. This method has been very much considered in recent years. Because of the high energy of the photons produced by the accelerator, it is necessary to protect the walls, roof and the floor of the treatment rooms using the concrete and leaden materials. One of these harmful radiations produced in radiation therapy centers is the Skyshine that should be considered in designing the shieldings. Skyshine rays are the primary beams that pass through the ceiling in the vertical direction and scatter in the upper atmosphere above the building and return to the ground; so they transfer radiation dose to a general area outside the radiotherapy room. This study aimed to evaluate and determine the levels of doses resulted from skyshine radiation in Shahid Rajaee Radiation Center of Babolsar in Northern Province of Iran and compare it with the values of international standards. Materials and Methods: In this survey dose measurement has been done with LS01 ion chamber (1000 cc) and Unidose E electrometer produced by PTW company in 6mv Elekta compact accelerator (made in Germany) with exposing 400MUs and field size of 40*40. The distances of dose measurement were 300, 150, 100, 50 and 25 cm from the external wall of the treatment room and 2.10cm height from the ground. Temperature, pressure and correction factors of electrometer and dosimeter has been considered in results and total dose of skyshine rays based on reformed reading of electrometer acquired for 50 weeks,6 days and 8 working hours. Results: The dose rate at 25, 50, 100, 150 and 300 cm distances from the external wall of the treatment room were 1.017, 0.79, 0.595, 0.436, 0.275 µsv/h respectively. Also, the standard deviations were 0.012, 0.007, 0.015, 0.020, and 0.032. Conclusion: The obtained results were compared with other studies and the annual average worldwide rate; the result was compatible with most studies and was less than the average worldwide= 2.4 mSv/y.
کلیدواژههای انگلیسی مقاله
Skyshine, Shielding, Medicalaccelerator, Ionization Chamber
نویسندگان مقاله
| Soodeh Satayi Mokhtari
Msc Student of Medical Physics Radiobiology and Radiation Protection Department, Faculty of Medicine, Babol University of Medical Sciences, Babol, Iran
| Ali shabestani Monfared
Professor of Medical Physics, Department of Medical Physics Radiobiology and Radiation Protection, Faculty of Medicine, Babol University of Medical Sciences, Babol, Iran
| Kourosh Arbabi
PHD of Medical Physics, SSDL, Iranian Atomic Energy Agency, Karaj, Iran
| Shahvar A
PHD of Medical Physics, SSDL, Iranian Atomic Energy Agency, Karaj, Iran
| Fatemeh Niksirat
MSc of Medical Physics Radiobiology and Radiation Protection Department, Faculty of Medicine, Babol University of Medical Sciences, Babol, Iran
| Kourosh Ebrahimnejad Gorji
PHD of Medical Physics, Department of Medical Physics Radiobiology and Radiation Protection, Faculty of Medicine, Babol University of Medical Sciences, Babol, Iran
| Werya Parwaie
PHD Student of Medical Physics and Biomedical Engineering Department, Tehran University of Medical Sciences, Tehran, Iran
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_12349.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Conference Proceedings
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات