این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
جمعه 28 آذر 1404
Iranian Journal of Medical Physics
، جلد ۱۵، شماره Special Issue-۱۲th. Iranian Congress of Medical Physics، صفحات ۸۲-۸۲
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
A study on the accuracy of motion tracking of thoracic tumors at radiotherapy with external surrogates
چکیده انگلیسی مقاله
Introduction: In radiotherapy with external surrogates, exact information of tumor position is one of the key factors that improves treatment delivery. Many dynamic tumors in thorax region of patient move mainly due to respiration and are known as intra-fractional motion error that must be compensated, as well. One of clinical strategy is using Stereotactic Body Radiation Therapy with external surrogates has been proposed to compensate motion error. In this strategy, prediction model is one of main component as responsible to track tumor motion in real time. In this study, a prediction model based on the fuzzy logic concept is proposed for real time tumor tracking during tumor treatment. Several approaches have been proposed for this aim using linear and non-linear prediction models, but a fuzzy environment may be optimal due to its robustness and benefits. Materials and Methods: The fuzzy model is configured using training dataset provided by monitoring systems with detecting tumor motion and external rib cage motion of ten patients treated with Cyberknife Synchrony System at Georgetown University Hospital. After configuring, the model is ready to trace tumor motion during therapeutic beam irradiation. In our study, we investigated the effect of the number of data clusters, fuzzy inference system type on the performance accuracy of our model. In order to assess the performance of our model, the predicted tumor motion was compared with respect to the state of the art model. Results: In this work we utilized Root Mean Square Error (RMSE) as common available mathematical metric for illustrating the performance uncertainty error of fuzzy prediction model. As resulted, the mean value of RMSE over ten patients is 5.45 mm Moreover, by implementing sugeno method the RMSE is remarkably less than the same calculation by means of Mamdani method. Moreover, the computational time will be significantly decreased using Sugeno type. As example, the run time improvement is almost 33% for one typical patient with left lob lung cancer. Conclusion:A fuzzy logic based prediction model was assessed in this work to predict tumor motion as real time during external radiotherapy. The benefits of implemented fuzzy inference system in model learning and its simplicity during running has made it feasible, robust and very promising for real clinical application.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
| Seyyed Amirreza Dastyar
Medical Radiation Division, Faculty of New Sciences and Technologies, Graduate University of Advanced Technology, Haftbagh St. Kerman, Iran, 7631818356
| Ahmad Esmaili Torshabi
Medical Radiation Division, Faculty of New Sciences and Technologies, Graduate University of Advanced Technology, Haftbagh St. Kerman, Iran, 7631818356
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_12360.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Conference Proceedings
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات