این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
جمعه 28 آذر 1404
Iranian Journal of Medical Physics
، جلد ۱۵، شماره Special Issue-۱۲th. Iranian Congress of Medical Physics، صفحات ۹۵-۹۵
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Assessment of patients’ entrance skin and effective dose in a mathematical human phantom for the most common interventional radiological examinations
چکیده انگلیسی مقاله
Introduction: Nowadays, we are witnessing an exponential use of interventional radiology techniques in different communities. After CT, interventional techniques are the second factor of increasing patients' doses in different societies. Measuring patient doses from aforementioned methods has been recommended by many radiation protection professional organizations such as ICRP and IAEA. Our aim was to measure/calculate the patients' entrance skin and also necessary parameters required to estimate relevant effective doses for common diagnostic and therapeutic interventional radiology examinations. Materials and Methods: After reviewing and analyzing interventional radiology examination data in an imaging center of a public hospital over 6 months, five most commonly used examinations, including cholangiography, chemoembolization liver, uterine fibroids embolization, bile duct stenting and coronary angiography and brain embolization were selected for the dose measurements/calculations. For each examination, 50 patients were selected and their skin doses were measured using TLDs. Effective doses resulted from these examinations were also calculated by using the Monte Carlo based PCXMC software for an average human phantom. Results: The average entrance skin dose measured for the patients undergoing cholangiography, chemoembolization liver, uterine fibroids embolization, bile duct stenting and coronary angiography and brain embolization examinations were: 57, 141, 447, 241, 587 mGy and their estimated effective doses were 3.5,11, 31, 15.5, 10 mSv respectively. As expected, the patient doses in interventional radiology examinations varied, since the amount of doses depends on many factors including the complexity and difficulty of interventional procedures, operators' experience and skill, and patients' weight. Conclusion: In interventional radiology examinations a small field of view is used. Hence, appropriate voltage potentials and pulse durations must be used to reduce effective doses while achieving highest image qualities (resolution, contrast-to-noise ratio, and signal to noise ratio).
کلیدواژههای انگلیسی مقاله
Interventional radiology, Entrance Skin Dose, Effective Dose
نویسندگان مقاله
| Bijan Hashemi
Ph.D., Associate Professor, Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran.
| Salar Bijari
M.Sc. Graduate, Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran.
| Hossein Ghanaati
Ph.D., Professor, Advanced Diagnostic and Interventional Radiology Research Center (ADIR), Tehran University of Medical Sciences, Tehran, Iran.
| Mohsen Bakhshandeh
Ph.D., Associate Professor, Department of Radiology, Faculty of Medical Sciences, Shahid Beheshti University, Tehran, Iran.
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_12423.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Conference Proceedings
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات