این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Iranian Journal of Medical Physics، جلد ۱۵، شماره Special Issue-۱۲th. Iranian Congress of Medical Physics، صفحات ۱۳۰-۱۳۰

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Evaluation of X-Ray Absorption by Ointment Containing Bismuth Oxide Nanoparticles in Radiology Staff
چکیده انگلیسی مقاله Introduction: The effects of X-rays on carcinogens have been proven in recent years. Today, lead is used in many devices such as lead covers, thyroid protectors to protect the body against x-rays. But this equipment contains many disadvantages such as, Toxicity, High weight and Lack of flexibility. Today, newer methods, such as semi-solid skin care products (cream, ointment), are used. In this study, the feasibility of using a cream containing bismuth oxide nanoparticles as an X-ray absorbent was studied.   Materials and Methods: Bismuth oxide nanoparticles structure (Bi2O3) and formulation in ointment form was surveyed. Then were formulated by a new method using sorbitol synthesis. The final cream consists of 70% bismuth oxide nanoparticles and 30% other ingredients. Then the absorption of x-rays in different thicknesses of ointment was evaluated. Results: A dosimetry test showed that the protective effect of ointment was significantly (P< 0.05) better than the lead Sheet as control group. Dosimetry tests showed that the ointment of bismuth oxide nanoparticles absorbed 56% of the radiation, but the lead just absorbed 41%. Bismuth K absorption edge is more than other metals and its nanoparticles have higher absorption surface to volume (S/V). Conclusion: Bismuth oxide nanoparticles, due to the high atomic number of bismuth, is more efficient than lead in X-ray absorption, and is less toxic. Bismuth oxide nanoparticles cream can be used as X-ray absorbent for various occupations such as doctors, dentists, operating room staff and radiologists, and increases the health and safety of the staff.
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله | Mohsen Shoja
Depatment of Radiology, Faculty of Paramedicine, Semnan University of Medical Sciences, Semnan, Iran. Tel: 00982333654162 Email: Moh3n_sh_66@semums.ac.ir


| Kamran Vahidizade
Student Research Committee, Semnan University of Medical Sciences, Semnan, Iran


| Mohadese Soleimani
Student Research Committee, Semnan University of Medical Sciences, Semnan, Iran



نشانی اینترنتی http://ijmp.mums.ac.ir/article_12624.html
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Conference Proceedings
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات