این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
پنجشنبه 27 آذر 1404
Iranian Journal of Medical Physics
، جلد ۱۵، شماره Special Issue-۱۲th. Iranian Congress of Medical Physics، صفحات ۱۴۰-۱۴۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Reduction of photon contamination in electron therapy of cancer with magnetic fields
چکیده انگلیسی مقاله
Introduction: Photon contamination is a restriction on treatment with electron that increase dose to healthy tissue below the tumor. The aim of this study is to reduce the photon contamination using a magnet system. Materials and Methods: A mini-applicator equipped with two neodymium boron permanent magnets was designed which make it possible to adjust the distance between magnets. Mini-applicator was placed in standard applicator of Varian 2100 CD linear accelerator. Mini-applicator was modeled in CST studio finite element software. Deflection angle and displacement of electron beam transporting through magnetic field were calculated. Different transverse magnetic intensities were created by determining the amount of 2 to 5 cm for distance between two poles. The treatment head was rotated to deflected electrons become normal to the water surface. Dosimetry was performed in a water phantom using EBT2 gafchromic film. Films were scanned with HP G3010 reflecting scanner. Optical density in red channel was extracted by programming in MATLAB. Dose curves in presence of magnetic field compared with frame without magnetic field. Results: Simulated and measured magnetic field intensities are consistent. Maximum deflection angle is 32.9 degree for 12 MeV and minimum deflection is 12.1 degree for 15 MeV electron beam. Scanned film showed clearly that photons exit from electron field. The photon contaminations without magnetic field were 4.5 and 2.6 percent for 15 and 12 MeV respectively which using highest magnetic field intensity have decreased to 0.9 and 0.2 percent. Conclusion: A magnetic mini-applicator was created and modeled using finite element method. The deflection angle and displacement of electrons beam was calculated. By applying magnetic field, photon contamination can be reduced. Energetic electrons can be used without concern for adverse effects on healthy depth tissue.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
| Mohammad Javad Tahmasebibirgani
Department of Medical Physics, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran Departments of Clinical Oncology, Golestan Hospital, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| Mohammad Ali Behrooz
Department of Medical Physics, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| Mansour Zabihzadeh
Department of Medical Physics, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| Hojatollah Shahbazian
Departments of Clinical Oncology, Golestan Hospital, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| Reza Maskani
School of Paramedicince, Shahroud University of Medical Sciences, Shahroud, Iran. Tel: +989124734697 Student Research Committee, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| Jafar Fatahiasl
Department of Radiology Technology, School of Paramedicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| Nahid Chegeni
Departments of Clinical Oncology, Golestan Hospital, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_12634.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Conference Proceedings
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات