این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Iranian Journal of Medical Physics، جلد ۱۵، شماره Special Issue-۱۲th. Iranian Congress of Medical Physics، صفحات ۱۵۰-۱۵۰

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Fast System Matrix Calculation in CT Iterative Reconstruction
چکیده انگلیسی مقاله Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- consuming components. In this study we propose a method for fast system matrix calculation based on line integral model (LIM) in a simultaneously algebraic reconstruction technique (SART) framework. This method has generality to extend to finite size beam and 3D geometry. Also we use our LIM based method to approximate the area integral for area integral model (AIM) based method. Materials and Methods: First, we calculate the contributing detectors for a given pixel and a given projection view. Then, the lengths of the intersection line from these detectors with the pixel are calculated using an efficient method. To approximate area integral, a narrow fan beam is modeled by several lines that connect the source to one detector cell. Finally the computed system matrix was evaluated by reconstructing the image of a numerical Shepp-Logan phantom, using SART. Results: Overall, numerical results show that our LIM-based method is faster than the Siddon algorithm. Our AIM-based method results in better image quality than LIM-based method but more time consuming. Conclusion: The authors have proposed fast algorithm to calculate system matrix, which are extendable for the finite-size beam and 3D geometry. The algorithm has the potential for parallel computing.
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله | Golshan Mahmoudi
Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran


| Mohammad Reza Ay
Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran. Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran


| Hossein Ghadiri
1. Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran. Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran



نشانی اینترنتی http://ijmp.mums.ac.ir/article_12650.html
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Conference Proceedings
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات