این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Iranian Journal of Medical Physics، جلد ۱۵، شماره Special Issue-۱۲th. Iranian Congress of Medical Physics، صفحات ۲۵۷-۲۵۷

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی New electrical device for field coincidence quality control test in linear accelerators
چکیده انگلیسی مقاله Testing of the coincidence of a linear accelerators X-ray field and the light field as a quality control test is often done in a subjective method, involving the manual marking of pieces of film and the visual inspection of the film after irradiation. The purpose of this study was to develop an objective method for performing this test, while also increasing the accuracy, precision and the speed of the test. The new method uses a portable, lightweight an inexpensive device containing optically-shielded and nonoptically-shielded photo diodes to detect the location and dimensions of the light and x-ray fields. The measurement results are analyzed and drawn using purpose-written user friendly software. This system is able to reliably measure the coincidence of the two fields with 0.5 mm accuracy and a standard deviation of 0.02 mm, which is well within the tolerance recommended by AAPM Task Group 42. This proposed method allows accurate and precise measurements to be obtained, through a largely automated process, resulting in measurements that have substantially reduced sensitivity to subjectivity    or human error, compared with the standard film-based technique.
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله | M.H. Bahreyni Toosi
Medical Physics Research Center, Medical Physics Department, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran


| Ghorban Safaeian layen
Department of Technology of Radiology, school of paramedical science, Mashhad University of Medical Science, Mashhad, Iran


| Ali Feyzi
Department of Technology of Radiology, school of paramedical science, Mashhad University of Medical Science, Mashhad, Iran


| Mahdi Heravian Shandiz
Department of Technology of Radiology, school of paramedical science, Mashhad University of Medical Science, Mashhad, Iran


| Amir Hossein Ziaei
Department of Technology of Radiology, school of paramedical science, Mashhad University of Medical Science, Mashhad, Iran


| Zahra emamverdian
Department of Biomedical Engineering, Islamic Azad University of Mashhad Branch, Mashhad, Iran