این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
پنجشنبه 27 آذر 1404
Iranian Journal of Medical Physics
، جلد ۱۵، شماره Special Issue-۱۲th. Iranian Congress of Medical Physics، صفحات ۲۶۳-۲۶۳
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
An Approach in Radiation Therapy Treatment Planning: A Fast, GPU-Based Monte Carlo Method
چکیده انگلیسی مقاله
Introduction: An accurate and fast radiation dose calculation is essential for successful radiation radiotherapy. The aim of this study was to implement a new graphic processing unit (GPU) based radiation therapy treatment planning for accurate and fast dose calculation in radiotherapy centers. Materials and Methods: A program was written for parallel running based on GPU. The code validation was performed by EGSnrc/ DOSXYZnrc. Moreover, a semi-automatic, rotary, asymmetric phantom was designed and produced using a bone, the lung, and the soft tissue equivalent materials. All measurements were performed using a Mapcheck dosimeter. The accuracy of the code was validated using the experimental data, which was obtained from the anthropomorphic phantom as the gold standard. Results: The findings showed that, compared with those of DOSXYZnrc in the virtual phantom and for most of the voxels (>95%), < 3% dose-difference or 3 mm distance-to-agreement (DTA) was found. Moreover, considering the anthropomorphic phantom, compared to the Mapcheck dose measurements, < 5% dosedifference or 5 mm DTA was observed. Conclusion: Fast calculation speed and high accuracy of GPU-based Monte Carlo method in dose calculation may be useful in routine radiation therapy centers as the core and main component of a treatment planning verification system.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
| Mojtaba Karbalee
School of Allied Medical Sciences, Zabol University of Medical Sciences, Zabol, Iran
| Daryoush Shahbazi Gahrouei
Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
| Mohammad B. Tavakoli
Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_12899.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Conference Proceedings
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات