این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
پنجشنبه 27 آذر 1404
Iranian Journal of Medical Physics
، جلد ۱۵، شماره Special Issue-۱۲th. Iranian Congress of Medical Physics، صفحات ۲۶۸-۲۶۸
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Independent assessment of source transit time for the BEBIG SagiNova® high dose rate brachytherapy afterloader
چکیده انگلیسی مقاله
Introduction: The dwell time and transit time components contribute to the overall delivered dose to patients in high dose rate (HDR) brachytherapy treatments. The transit time results from source entry and exit as well as source movements between dwell positions. It depends on various parameters such as the source speed profile, source indexer distance to dwell position, and step size. Usually brachytherapy treatment planning systems do not apply a correction for transit time and the afterloader unit itself adjusts the final dwell times taking account of the transit time. The independent verification of transit time for each HDR afterloader is recommended before clinical use. Some published reports have used a video camera and/or stopwatch to perform this task. To the best of our knowledge, there is no published report of transit time measurement for the recently released BEBIG SagiNova® HDR afterloader unit. The goal of this study is to independently evaluate the corrected source transit time of this afterloader unit without using a video camera or stopwatch. Materials and Methods: The assessed unit was a newly installed SagiNova® 60Co HDR afteroloader (software version 1.2.4; Eckert & Ziegler BEBIG GmbH). A dosimetric method was used. The measurements were performed using a previously commissioned PTW source check4п (type 33005) well- type ionization chamber and UNIDOS E® electrometer. A 30 cm plastic needle and a 100 cm transfer tube were used to accurately place the source at the point of maximum response ('sweet spot') of the well chamber. Plans were generated using SagiPlan version 2.0 to irradiate the well chamber for dwell times of 3, 5, 10, 15, 20, 30, 40, 60, and 120 s. All the measurements were repeated three times. The transit time following its correction by the afterloader software were assessed using the ESTRO-recommended approach of obtaining transit time correction factors and another strategy established for teletherapy sources. The results obtained using the two strategies were also compared. Results: For the measured setup, the transit time was 0.7 s using both methods. The mean ESTRO transit time correction factor was 0.93 (range 0.88 to 0.99 for dwell times of 3 to 120 s). Conclusion: This work demonstrates an accurate dosimetry-based method to measure source transit time during the commissioning step of HDR BT afteroloaders, using a practical approach and available standard equipment. It also shows the consistency of the results between the two dosimetric methods of obtaining source transit time. The results suggest that the afterloader software correction does not completely eliminate this effect, which results in slightly longer irradiation times.
کلیدواژههای انگلیسی مقاله
Brachytherapy, High Dose Rate, Transit time, BEBIG, SagiNova
نویسندگان مقاله
| Abolfazl Kanani
Ionizing and Non-Ionizing Radiation Protection Research Center (INIRPRC), Shiraz University of Medical Sciences, Shiraz, Iran Student research committee, Shiraz University of Medical Sciences, Shiraz, Iran
| Sareh Karbasi
Physics Unit, Department of Radiotherapy and Oncology, Shiraz University of Medical Sciences, Shiraz, Iran
| Mohammad Amin Mosleh-Shirazi
Ionizing and Non-Ionizing Radiation Protection Research Center (INIRPRC), Shiraz University of Medical Sciences, Shiraz, Iran Physics Unit, Department of Radiotherapy and Oncology, Shiraz University of Medical Sciences, Shiraz, Iran
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_12912.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Conference Proceedings
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات