این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
جمعه 28 آذر 1404
Iranian Journal of Medical Physics
، جلد ۱۵، شماره Special Issue-۱۲th. Iranian Congress of Medical Physics، صفحات ۲۸۵-۲۸۵
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Quality assurance prusedore in high dose rate bracythrapy
چکیده انگلیسی مقاله
Introduction: Quality assurance is essential for obtaining the best achievable tumor control, avoiding unnecessary side effects, accuracy and safety during performing High Dose Rate (HDR) Brachytherapy (BT). Quality assurance is extremely important because HDR BT procedures are performed quickly, with high doses given in a short time period, with little opportunity for correction. The quality assurance procedure can be divided into the four categories: Treatment unit, Treatment Planning System (TPS), Imaging and Patient treatment procedure. These categories include different tests which should to be done periodically in order to verify the accurate treatment. In this study a number of important quality assurance tests were performed. Materials and Methods: Physical and Safety parameters of the Sagi Nova (Eckert & Ziegler Bebig GmbH) machine with Co-60 source was investigated. Determination of source position accuracy was done in two methods 1) video-ruler source position and 2) Gafchromic film with posi check phantom (PTW, Germany). Reference Air Kerma Strength (RAKS) of the source was measured according to IAEA TECDOC-1274 using a well-type ionization chamber (PTW, Germany) with suitable holder for insertion of the afterloader's catheter. Another physical parameter like Length of treatment tubes, Transit time, Timer consistency and Timer linearity were measured. Safety parameters like Communication equipment, Applicator attachment, Catheter attachment lock, Door interlock, warning lights, Room monitor, Hand held monitor, Treatment interrupt, and Emergency stop were evaluated. Results: All items related to safety parameters investigated and defects have been resolved. Source positioning accuracy in both video-ruler and Gafchromic measurement showed a difference of less than one millimeter. RAKR measured by the well-type ionization chamber in comparison with the input value in the TPS showed a 0.5% difference which is acceptable. Conclusion: Quality assurance of Sagi Nova HDR BT machine was performed. Physical and Safety parameters were investigated. The measurements showed acceptable results. Because of the high importance of HDR BT treatment, it is recommended each center perform quality assurance tests according to the existing protocols in the regular time interval.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
| Ali Rajabi
Secondary Standard Dosimetry Laboratory (SSDL), Pars isotope Co., Karaj, Iran.
| Mohsen bakhshandeh
Associate Professor, Radiology Technology Department, Allied Medical Faculty, Shahid Beheshti University of Medical Science,Tehran, Iran
| Ali Jabbari arfaei
Tajrish Shohada Hospital, Tehran, Iran.
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_12934.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Conference Proceedings
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات