این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
جمعه 28 آذر 1404
Iranian Journal of Medical Physics
، جلد ۱۵، شماره Special Issue-۱۲th. Iranian Congress of Medical Physics، صفحات ۳۳۲-۳۳۲
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Determination of an Effective Wedge Angle by Combination of Two Arbitrary Universal Wedge Fields in Radiation Therapy of Cancer Patients with Megavoltage Photon Beams.
چکیده انگلیسی مقاله
Introduction: Wedge filters are commonly used in radiation oncology for eliminating hot spots and creating a uniform dose distribution in optimizing isodose curves in the target volume for clinical aspects. These are some limited standard physical wedges (15°, 30°, 45°, 60°), or creating an arbitrary wedge angle, like motorized wedge or dynamic wedge, ... The new formulation is presented by the combination of wedge fields for determining an arbitrary effective wedge angle. The isodose curves also are derived for these wedges. Materials and Methods: we performed the dosimetry of Varian Clinac 2100C/D with Scanditronix Wellhofer water blue phantom, CU500E, OmniPro - Accept software and 0.13cc ionization chamber for 6Mv photon beam in depth of 10cm (reference depth) for universal physical wedges (15°, 30°, 45°, and 60°) and reference field 10x10cm2. By combining the isodose curve standard wedge fields with compatible weighting dose for each field, the effective isodose curve is calculated for any wedge angle. Results: The relation between a given effective wedge angle and the weighting of each combining wedge fields was derived. A good agreement was found between the measured and calculated wedge angles and the maximum deviation did not exceed 3°. The difference between the measured and calculated data decreased when the combined wedge angles were closer. The results are in agreement with the motorized single wedge appliance in the literature. Conclusion: This technique showed that the effective wedge angle that is obtained from this method is adequate for clinical applications and the motorized wedge formalism is a special case of this consideration.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
| Azin Shamsi
Department of Medical physics, Golestan Hospital, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| Mohammad Javad Tahmasebi Birgani
Department of Medical physics, Golestan Hospital, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| Mohammad Ali Behrooz
Department of Medical physics, Golestan Hospital, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| Shole Arvandi
Department of Clinical Oncology, Golestan Hospital, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| Jafar Fatahiasl
Department of Medical physics, Golestan Hospital, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| Reza Maskny
Department of Medical physics, Golestan Hospital, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| Neda Abdalvand
Department of Medical physics, Golestan Hospital, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_12986.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Conference Proceedings
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات