این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Iranian Journal of Medical Physics، جلد ۱۵، شماره Special Issue-۱۲th. Iranian Congress of Medical Physics، صفحات ۳۴۳-۳۴۳

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Evaluation of CorePlanTM treatment planning system for 6 and 15 MV photon irradiation
چکیده انگلیسی مقاله Introduction: Radiotherapy is an effective modality to treat esophageal carcinoma. Due to various inhomogenous tissues with a variety of physical and radiological properties which can cause uncertainty in accurate dose calculations in radiation therapy, accuracy of TPS is very important. The aim of this study was to quantify dose calculation accuracy of CoreplanTM TPS in an inhomogenous home-made phantom.   Materials and Methods: Thermoluminescent dosimeter-100 (TLD-100) chips were used within inhomogeneous home-made phantom for dose measurement; CoreplanTM was also applied for dose calculation. Finally, difference between measured doses and calculated doses was gotten to calculate dosimetry accuracy of the TPS at PTV and neighbor's organ at risks region.   Results: Findings indicated that for regions near PTV, Coreplan TPS leads to an overdose estimation up to 2.3% and 4.8% for the 6 and 15 MV energies, respectively and in regions far from primary field, the Coreplan TPS underestimated the dose compared to the measurements which might be due to scattered radiation that is not well considered in the TPS.   Conclusion: Due to the inhomogeneous in the thorax region, the dose calculation accuracy of TPS should be appropriate. The agreement criterion was determined according to ICRU recommendation, which suggest the accuracy of ±5% in the delivery of an absorbed dose to a target volume. According to the results, it is concluded that the accuracy of dose calculation of Coreplan TPS showed good agreement with experimental data.
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله | Danial Seifi Makrani
Department of Biochemistry and Biophysics, Faculty of Medicine, Mazandaran University of Medical Sciences, Sari, Iran.


| Tayyeb Pourfallah
Department of Biochemistry and Biophysics, Faculty of Medicine, Mazandaran University of Medical Sciences, Sari, Iran.



نشانی اینترنتی http://ijmp.mums.ac.ir/article_12996.html
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Conference Proceedings
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات