این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
پنجشنبه 27 آذر 1404
Iranian Journal of Medical Physics
، جلد ۱۵، شماره Special Issue-۱۲th. Iranian Congress of Medical Physics، صفحات ۳۴۴-۳۴۴
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Comparison of radiotherapy techniques to reduce hematologic toxicity in whole pelvic radiation therapy
چکیده انگلیسی مقاله
Introduction: Concurrent chemoradiotherapy (CRT) is a standard treatment method for patients with carcinoma of cervix. Despite admirable therapeutic results, acute hematologic toxicity (HT) is common with this regimen. Many studies evaluate the relationship between the bone marrow dosimetric parameters and the severity of HT and result shown that the low dose of bone marrow would decrease the incidence of HT in patient undergoing concomitant CRT. In this study the dosimetric parameters of two radiotherapy plans in managing of cervix cancer has been evaluated to investigate the best plan on the way of reducing bone marrow dose. Materials and Methods: Computed tomography scans of 18 patients with carcinoma of cervix were acquired and transferred to the 3D treatment planning system. The corePlan3D treatment planning system was used to contour all of the structures and to compute the dose distribution for plans based on collapsed cone convolution (CCC). For each patient, two different treatment plan were prepared using 15 MV photon energies. The minimum dose (Dmin), maximum dose (Dmax) and mean dose (Dmean) to target (PTV) and femoral head were compared for each plan. Results: Result shown that our manipulated four-field plan which use anterior oblique beams seemed to deliver a lower mean dose to femoral head against conventional box fields (Dmean=66.7±3.1 cGy, 98.8±7.3 cGy, Dmax=117.5±3.0 cGy, 126.9±4.3 cGy, respectively) and deliver sufficient dose to PTV (Dmax=213.5±4.2 cGy, 194.6±2.0 cGy, respectively). Conclusion: With suspicious planning in respect to choice of beam angles, beam weighting, and appreciation of potential exposure of normal tissues to exit dose, this study revealed that compared with conventional box fields, anterior oblique beams can achieve significant reductions in the dose to BM with adequate dose coverage to the PTV with an accurate beam arrangement
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
| Tayyeb Pourfallah
Associated Professor, Department of Biochemistry, Biophysics and Genetic, Faculty of Medicine, Mazandaran University of Medical Sciences, Sari, Iran. Mailing Address: Payambar Azam (PBUH) Academic Complex, 18km of Khazar-abad Road, Sari, Iran.
| Danial Seifi Makrani
Department of Biochemistry, Biophysics and Genetic, Faculty of Medicine, Mazandaran University of Medical Sciences, Sari, Iran
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_12997.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Conference Proceedings
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات