این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
پنجشنبه 27 آذر 1404
Iranian Journal of Medical Physics
، جلد ۱۵، شماره Special Issue-۱۲th. Iranian Congress of Medical Physics، صفحات ۳۶۲-۳۶۲
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Statistical uncertainty estimation in the calculation of the proton range in water phantom.
چکیده انگلیسی مقاله
Introduction: GATE (Geant4 Application for Tomographic Emission) is a Monte Carlo simulation platform developed by the OpenGATE collaboration since 2001 and first publicly released in 2004. In Geant4, each physics process is described by a model (several models are sometimes available for a given physics process) and a corresponding cross-section table. All Geant4 physics models and cross-sections below 10 GeV are now available in GATE. In particular, models describing the transport of optical photons and hadronic interactions have recently been introduced. The purpose of this study is to investigate the physics lists of the Geant4 code, as well as to examine the accuracy of energy deposition and statistical uncertainty in the calculation of the dose. Materials and Methods: In this study, GATE code was used to compute absorbed dose and fluence of protons in the energy range of 50-200 MeV and with energy step of 50 MeV. A water phantom (40*40*40 cm3) was modeled in a vacuum world volume (5*5*5 m3). Several physics lists have been defined in the GATE code that we used FTFP_BERT. The mono-energetic protons were emitted mono-directionally from a point source at one end of the water phantom. The DoseActor has been added to store distributions of dose with the associated statistical uncertainty in any volume The simulations were carried out for 10^6 proton histories that yielded better than 0.3% statistical errors. Results: In the current study, we obtained normalized energy deposited for 5-200 MeV proton beams as a function of depth in water and its associated relative statistical uncertainty. The statistical uncertainty for all voxels before the Bragg peak is below 0.01%. Fluctuations after the Bragg peak are due to near zero values of deposited energy at these depths. Conclusion: The results of this study showed that the statistical uncertainty of the dose in the energy of 200 MeV is about 0.25%. And by calculation the difference of proton ranges in this energy with NIST data, it is seen that this difference is greater than the statistical uncertainty. In order to obtain more accurate results, it is suggested that the accuracy of other physics lists is also examined..
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
| Shiva Zarifi
MSc. Student of medical physics, Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran. 2.Professor of medical physics, Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran.
| Hadi Taleshi Ahangari
Professor of medical physics, Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran.
| Sayyed Bijan Jia
Professor of physics, Department of Physics, Bojnord University, Bojnord, Iran.
| Mohammad Ali Tajik Mansoury
Professor of medical physics, Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran.
| Elham Kashian
MSc. Student of Biomedical Engineering, Department of Biomedical Engineering, Kermanshah University of Medical Sciences, Kermanshah, Iran
| Peyman Hejazi
Professor of medical physics, Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran.
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_13026.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Conference Proceedings