این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
جمعه 28 آذر 1404
Iranian Journal of Medical Physics
، جلد ۱۵، شماره Special Issue-۱۲th. Iranian Congress of Medical Physics، صفحات ۳۶۵-۳۶۵
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Assessment of a 2D EPID-based Dosimetry Algorithm for Pre-treatment and In-vivo Midplane Dose Verification
چکیده انگلیسی مقاله
Introduction: The use of electronic portal imaging devices (EPIDs) is a method for the dosimetric verification of radiotherapy plans both pretreatment and in-vivo. The aim of this study was to test a 2D EPID-based dosimetry algorithm for dose verification of some plans inside a homogenous and anthropomorphic phantom and in-vivo, as well. Materials and Methods: Dose distributions were reconstructed from EPID images using a 2D EPID dosimetry algorithm inside a homogenous slab phantom for a simple 10×10 cm2 box technique, the 3D conformal (prostate, head-and-neck and lung) and an IMRT prostate plans inside an anthropomorphic (Alderson) phantom and the patients (one fraction in-vivo) for the 3D conformal plans (prostate, head-and-neck and lung). Results: The Planned and EPID dose difference at isocenter, on average, was 1.7% for the pretreatment verification and was less than 3% for all in vivo plans except a head-and-neck which was 3.6%. The mean γ values for a 7-field prostate IMRT plan delivered to the Alderson phantom varied from 0.28 to 0.65. For 3D conformal plans applied for the Alderson phantom, all γ1% values were within the tolerance level for all plans and in both AP-PA beams. Conclusion: The 2D EPID-based dosimetry algorithm provides an accurate method to verify the dose of a simple 10×10 cm2 fields in two dimensions inside a homogenous slab phantom as well as for IMRT prostate plan and 3D conformal plans (prostate, head-and-neck and lung plans) applied using an anthropomorphic phantom and in-vivo.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
| Ali Jomehzadeh
Department of Medical Physics, Kerman University of Medical Sciences, Kerman, Iran. Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
| Parvaneh Shokrani
Department of Medical Physics, Isfahan University of Medical Sciences, Isfahan, Iran.
| Mohammad Mohammadi
.Medical Physics Department, Royal Adelaide Hospital. Adelaide, SA 5000, Australia
| Alireza Amouheidari
Department of Radiation Oncology, Isfahan Milad Hospital, Isfahan, Iran.
| Anton Mans
Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
| Ben Mijnheer
Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_13029.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Conference Proceedings
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات