این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
جمعه 28 آذر 1404
Iranian Journal of Medical Physics
، جلد ۱۵، شماره Special Issue-۱۲th. Iranian Congress of Medical Physics، صفحات ۳۶۶-۳۶۶
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Interpretation of In-air Output Ratio of Wedged Fields in Different Measurement Conditions
چکیده انگلیسی مقاله
Introduction: The head scatter factor (Sc) is one of the important parameters for monitor unit (MU) calculation. There are multiple factors that impact the Sc values, such as, head structures, back scattering in to dose monitoring chambers, wedges and so on. This study aimed to investigate the variations of SC with different build-up cap materials, wall thickness, Source to Skin Distance (SSDs), ionization chambers and variation of the SC with wedge angles in 6MV photon beam. Materials and Methods: In this study, Copper and Perspex build-up caps were designed and fabricated with two different thicknesses for each build-up cap. Measurements were performed on an Elekta Compact medical linear accelerator (6 MV) using RK with sensitive volume of 0.12 cc and Farmer-type ion chamber with sensitive volume of 0.65 cc. In all measurements, build-up caps and ionization chambers were positioned in a stand vertical to the beam central axis. It is also investigated the effect of different SSDs on SC. Results: The presence of wedge influences the SC values significantly. Variation of SC in open and wedged fields had maximum deviation of 0.9% and 6.8% and minimum of 0.4% and 2.7% for 30° and 60° angles of wedge, respectively. different SSD and type of ion chamber had no significant influence on the SC. In small field sizes, the SC values in copper build-up cap is higher than Perspex and in large field sizes, measured SC in perspex build-up cap is higher than copper. Conclusion: It was found that the presence of internal wedge has significant contribution to head scatter factor and it increases with increasing wedge angle. Therefore, it should be takes into account in manually MU calculations.
کلیدواژههای انگلیسی مقاله
Head Scatter Factor, Wedge, Ionization Chamber, Build-up cap
نویسندگان مقاله
| Faride Biglari
Department of Medical Physics, Tabriz University of Medical Sciences, Tabriz, Iran.
| Parinaz Mehnati
Medical Radiation Sciences Research Team, Department of Medical Physics, Tabriz University of Medical Sciences, Tabriz, Iran.
| Ali Jomehzadeh
Department of Medical Physics, Kerman University of Medical Sciences, Kerman, Iran.
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_13030.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Conference Proceedings
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات