Effect of Material and Wall Thickness Buildup Caps on the Head ScatterFactor Measurements in Irregular Fields Shielded by Cerrobend
چکیده انگلیسی مقاله
Introduction: The head scatter factor (Sc) is important to measurements radiation beam and beam modeling of treatment planning systems used for advanced radiation therapy techniques. This study aimed to investigate the design of a mini-phantom to measurement variations in collimator Sc in the presence of shielding blocks for shaping the beam using different field sizes. Martials and Methods: Copper, Brass, and Perspex buildup caps were designed and fabricated locally as material with three different thicknesses for buildup caps (mini- phantoms). Measurements were performed on an Elekta Compact medical linear accelerator (6MV) in Shafa Kerman Hospital, Iran. The Farmer-type ion chamber FG65-P (Scanditronix, Wellhofer) was used for all measurements. To measure the Sc, mini-phantom was positioned in a stand vertical to the beam central axis. Results: The data indicated that the Sc measurements using different buildup cap materials and thicknesses in 5 × 10, 7.5 × 7.5, and two 10 × 10 cm Cerrobend shield blocks ranged 0.98 to 1.00, 1.04 to 1.05, and 1.04 to 1.06, respectively. Also, it was observed that by increasing the block shield area from 50 cm2 to both 56.25 and 100 cm2, the Sc increased in all situations. Conclusion: We concluded using Brass compared to Perspex and Copper has less uncertainty due to its simple preparation and cutting which is useful to measurement of variations in collimator Sc.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
| Vahid Jahanbakhsh
Department of Radiotherapy Physics, Shafa Kerman Hospital, Kerman, Iran.
| Daryoush Shahbazi-Gahrouei
Department of Medical Physics, Isfahan University of Medical Sciences, Isfahan, Iran.
| Ali Jomehzadeh
Department of Medical Physics, Kerman University of Medical Sciences, Kerman, Iran