Iranian Journal of Medical Physics
، جلد ۱۵، شماره Special Issue-۱۲th. Iranian Congress of Medical Physics، صفحات ۳۷۱-۳۷۱
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Effective Source-Surface Distance in Various Field Sizes and Electron Beam Energies and its Effect on Cutout Factor in a Elekta Precise Linear Accelerator
چکیده انگلیسی مقاله
Introduction: In electron beam treatment, because of the non-point electron beam source, inverse-square law cannot be applied for dosimetry in different treatment intervals. Therefore, providing source-surface distance (SSD) charts in all clinics is of paramount importance. This study aimed to determine the effective SSD for various electron beam energies and field sizes and to evaluate its effect on cutout factor in a linear accelerator. Materials and Methods: We used Elekta Precise linear accelerator in Ayatollah Khansari Hospital, Arak, Iran, for various energy levels (10, 15, and 18 MeV). The measurement environment was MP3-M water phantom (PTW Co., Canada), and diode detector was utilized for dosimetry. The effective SSD and cutout factor was estimated for 100, 105, 110, 115, and 120 cm SSDs and 1.5×1.5 and 20×20 cm2 square fields. Results: The effective SSD in the 1.5×1.5 to 20×20 cm2 fields altered from 29.95 to 93.95 cm, 50.40 to 96.50 cm, and 63.51 to 95.32 cm for different energy levels of 10 MeV, 15 MeV, and 18 MeV, respectively. The cutout factor increased along with the field size, but decreased by extending the SSD. These alterations were more significant for the energy level of 10 MeV. Conclusion: Since the effective SSD is dependent on energy level and field size, it is recommended to independently compute the effective SSD considering these variables. Furthermore, for designing accurate therapies, cutout factor variations should be considered for small-sized fields, especially at low energy levels.
کلیدواژههای انگلیسی مقاله
Cutout factor, Electron Beams, Effective SSD, Field
نویسندگان مقاله
| Fateme Fallahi
Department of Medical Physics, School of Paramedical Sciences, Kashan University of Medical Sciences, Kashan, Iran
| Mohamad Reza Bayatiani
Department of Medical Physics and Rariotherapy, Arak University of Medical Sciences and Khansari Hospital, Arak, Iran
| Fatemeh Seif
Department of Medical Physics and Rariotherapy, Arak University of Medical Sciences and Khansari Hospital, Arak, Iran
| Akbar Aliasgharzadeh
Department of Medical Physics, School of Paramedical Sciences, Kashan University of Medical Sciences, Kashan, Iran
| Fatholah Mohaghegh
Department of Medical Physics and Rariotherapy, Arak University of Medical Sciences and Khansari Hospital, Arak, Iran
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_13035.html
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Conference Proceedings
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات