این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Iranian Journal of Medical Physics، جلد ۱۵، شماره Special Issue-۱۲th. Iranian Congress of Medical Physics، صفحات ۴۱۶-۴۱۶

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Primary efforts to optimize image quality in chest direct digital radiography of pediatric patient (for the age group 0 to 1 and 1 to 5 years) with survey some effective parameters in image quality and patient dose
چکیده انگلیسی مقاله Introduction: This study, evaluate pediatric digital radiography. Due to the high rates of this test and the high sensitivity of children to ionizing radiation in comparison with adults, it is attempted to achieve near optimal conditions by reducing the dose and maintaining the image quality. The object of the study is to change the irradiation parameters such as kV and mA and change them to a point where the dose is as high as possible for improved image quality or image quality preservation. Materials and Methods: Irradiation data from 50 children were collected for each of 2 age groups 0-1and 1-5 years old, and the mean values of voltage, current, and tube-to-table distance were obtained. To investigate Improving image quality as the dose reduced, a homogeneous phantom was constructed to produce an equivalent chest distribution with less than 5% accuracy. The Monte Carlo simulation and the equivalent human phantom ORNL were used to make this phantom. Then, with use of a digital radiographic system and dosimetric instruments that calculate the dose, the dose of homogeneous phantom was measured. Subsequently, irradiation parameters such as kV and current were changed to provide voltages higher than reference voltage and lower current flow rates than those referring to a dose lower than the reference dose, the choice of these conditions is due to the decrease in absorption dose. Finally, three parameters MTF, SNR and CNR are measured using the tools designed in this phantom. Results: With the results obtained for three parameters of each of the two age groups, the result was that for the age group 0-1, the best selection for the voltage and current was 60 and 2.5, respectively, in which the dose reduced and image quality increased. For 1 -5 years the voltage 75 with a current range of 3.2 to 5 mAs was close to optimum. Conclusion: This article has determined wide variations in radiation dose of x-ray examinations. Also, to Reduce patient dose and enhance image quality is suggested following solutions: 1-               utilization of Automatic Exposure Control (Of course, it's not easy to use for children with small body) 2-               Used additional filters such as copper: This filter by removing low-energy beam makes the beam harder, and photoelectric effect reduced, as a result, the patient dose is reduced. The works that was done in this study: Improving the exposure parameter compared to dose reference extracted 50 images for each age group and as well as improved its image quality.
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله | Behzad Mohsenzadeh
Department of Medical Physics and Biomedical engineering, Faculty of Medicine, Shahid Beheshti University of Medical Sciences and Health Services, Tehran


| Fereshte Rahmani
Department of Medical Physics and Biomedical engineering, Faculty of Medicine, Shahid Beheshti University of Medical Sciences and Health Services, Tehran


| Zeinab Kaveh
Department of Medical Physics and Biomedical engineering, Faculty of Medicine, Shahid Beheshti University of Medical Sciences and Health Services, Tehran


| Khatereh Shamsi
MSc in radiobiology Department of Medical Physics Babol University of Medical Sciences


| Hamed Bagheri
Radiation & wave research center Aja University of Medical Sciences


| Mohammad Reza Deevband
Department of Medical Physics and Biomedical engineering, Faculty of Medicine, Shahid Beheshti University of Medical Sciences and Health Services, Tehran, Iran TEL: 09123044609, E-mail: mdeevband@sbmu.ac.ir


| Leila Azimi
Departeman of imaging, Velayat hospital, University of medical science, Qazvin, Iran



نشانی اینترنتی http://ijmp.mums.ac.ir/article_13076.html
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Conference Proceedings
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات