این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
چهارشنبه 26 آذر 1404
Iranian Journal of Medical Physics
، جلد ۱۶، شماره ۴، صفحات ۲۸۵-۲۹۳
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Evaluation of Dose Calculation Algorithms Accuracy for Eclipse, PCRT3D, and Monaco Treatment Planning Systems Using IAEA TPS commissioning tests in a Heterogeneous Phantom
چکیده انگلیسی مقاله
Introduction: The accuracy of dose calculation algorithm (DCA) is highly considered in the radiotherapy sequences. This study aims at assessing the accuracy of five dose calculation algorithms in tissue inhomogeneity corrections, based on the International Atomic Energy Agency TEC-DOC 1583. Material and Methods: A heterogeneous phantom was scanned using computed tomography and tests were planned on three-dimensional treatment planning systems (3D TPSs) based on IAEA TEC-DOC 1583.Doseswere measured for 6- and 18-MV photon beams with ion chambers and then the deviation between measured and calculated TPS doses were reported. The evaluated five DCAs include Monte Carlo (MC) algorithm employed by Monaco, pencil beam convolution (PBC) and anisotropic analytical algorithms (AAA) employed by Eclipse and Superposition (SP), and Clarkson algorithms employed by PCRT3D TPSs. Results: In Clarkson algorithm, low and high energy photons indicated 7.1% and 14.8% deviations out of agreement criteria, respectively. The SP, AAA, and PBC algorithms indicated 0.9%, 7.4%, and 13.8% for low energy photon and 9.5%, 21.3%, and 23.2% for high energy photon deviations out of agreement criteria, respectively. However, MC algorithm showed 1.8% and less than 1% deviations at high and low energy photons, respectively. Conclusion: The DCAs had different levels of accuracy in TPSs. Some simple DCAs, such as Clarkson, showed large deviations in some cases. Therefore, the transition to more advanced algorithms, such as MC would be desirable, particularly for the calculation in the presence of inhomogeneity or high energy beams.
کلیدواژههای انگلیسی مقاله
Dose, Algorithm, Treatment Planning, Radiation Therapy
نویسندگان مقاله
| Nasibeh Kavousi
Department of Medical Physics and Medical Engineering, Faculty of Medicine, Tehran University of Medical Sciences, Tehran, Iran.
| Hassan Ali Nedaie
radiotherapy oncology department, cancer research centre, Tehran university of medical sciences,Tehran,Iran
| Somayeh Gholami
1. Department of Medical Physics and Medical Engineering, Faculty of Medicine, Tehran University of Medical Sciences, Tehran, Iran. 2. Radiotherapy Oncology Research Centre, Cancer Institute, Tehran University of Medical Sciences, Tehran, Iran.
| mahbod Esfahani
Radiotherapy Oncology Research Centre, Cancer Institute, Tehran University of Medical Sciences, Tehran, Iran.
| Ghazale Geraily
Department of Medical Physics, Tehran University of Medical Science, Tehran, Iran
نشانی اینترنتی
http://ijmp.mums.ac.ir/article_11821.html
فایل مقاله
اشکال در دسترسی به فایل - ./files/site1/rds_journals/145/article-145-1651790.pdf
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
Original Paper