این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
چهارشنبه 26 آذر 1404
The Archives of Bone and Joint Surgery
، جلد ۷، شماره ۴، صفحات ۰-۰
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Correlation of Anthropometric Measurements of Proximal Tibia in Iranian Knees with Size of Current Tibial Implants
چکیده انگلیسی مقاله
Background and objectives: Clinical studies have reported that Asian knee anatomical aspects are smaller than the Caucasian population. The purpose of this study was to investigate morphometry of proximal tibia in standard resected surface of total knee arthroplasty. Materials and methods: In this descriptive research in 2015, anthropometric data of proximal tibia were measured in 132 knees (80 males and 52 females) using magnetic resonance imaging (MRI). Data included anteroposterior (AP) length, mediolateral (ML) width, medial AP (MAP), lateral AP (LAP) and aspect ratio (ML/AP). The medial and lateral AP distance to bone center was calculated for symmetry analysis. The morphometric data were also compared with the same dimensions of four current tibial implants. Results: The mean age of subjects was 38.26 ± 11.45 year (20-60 years). The mean AP length and the mean ML width in the resected surface of bone as well as the mean aspect ratio (ML/AP) of tibial bone in all subjects were respectively 46.53±4.05 mm, 73.36±6.86 mm and 1.58±0.11 mm. The medial and lateral AP distance up to bone center were respectively 13.40±6.17 mm and 17.09±6.83 mm, indicating asymmetric proximal tibia in the study population. Conclusion: Measurements of anatomic shapes and dimensions of proximal tibial revealed that women have smaller dimensions than their male counterparts. Prostheses with smaller AP size tended to be undersized and larger AP size had tendency towards overhang in the mediolateral dimension. Data and the results of this study can be used as a guide to design tibial implant components suitable for total knee arthroplasty in Iranian population.
کلیدواژههای انگلیسی مقاله
Proximal Tibia, knee, Implant, MRI, Morphometry
نویسندگان مقاله
| Elham karimi
MSc of anatomical science, Department of biology and anatomical sciences, faculty of medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
| Reza Zandi
Assistant Professor of Orthopedic surgery, Taleghani hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
| Mohsen Norouzian
Associate Professor, Department of biology and anatomical sciences, school of medicine, shahid Beheshti University of medical sciences, Tehran, Iran
| Ali Birjandinejad
Associated Professor of Orthopedic surgery, Orthopedic Research Center, Shahid Kamyab Hospital, Mashhad University of Medical Sciences, Mashhad, Iran
نشانی اینترنتی
http://abjs.mums.ac.ir/article_12492.html
فایل مقاله
اشکال در دسترسی به فایل - ./files/site1/rds_journals/328/article-328-1668097.pdf
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
RESEARCH PAPER
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات