این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
Journal of Computational and Applied Research in Mechanical Engineering - JCARME، جلد ۹، شماره ۱، صفحات ۱-۱۸

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی An advection-diffusion multi-layer porous model for stent drug delivery in coronary arteries
چکیده انگلیسی مقاله Arterial drug concentration distribution determines local toxicity. The safety issues dealt with Drug-Eluting Stents (DESs) reveal the needs for investigation about the effective factors contributing to fluctuations in arterial drug uptake. The current study focused on the importance of hypertension as an important and controversial risk factor among researchers on the efficacy of Heparin-Eluting Stents (HES). For this purpose, the effect of blood pressure is systematically investigated in certain cardiac cycle modes. A comprehensive study is conducted on two classes, pulsatile (time-dependent), to have a more realistic simulation, and non-pulsatile (time-independent) blood flow, each one in four modes. The governing equations applied to drug release dynamics are obtained based on porous media theory. The equations are solved numerically using Finite Volume Method (FVM). Results reveal that there is a significant difference when the plasma flow considered and when it is neglected (regardless of time dependency). Moreover, the concentration level is more decreased in pulsatile blood flow rather than the non-pulsatile blood flow, although the penetration depth for pressure and concentration are nearly 20% and 5% of the wall thickness, respectively. In other words, the mass experienced by the arterial wall is lower in pulsatile blood flow in comparison to non-pulsatile blood flow. As a consequence, the risk of toxicity is declined as the blood pressure increases. Also, it can be seen that the polymer is diffusion-dominated so that no significant changes in the release characteristics are observed in the presence of the plasma filtration.
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله Seyed Masoud Vahedi |
Faculty of Mechanical Engineering, Semnan University, Semnan

Mohammad Sadegh Valipour |
Faculty of Mechanical Engineering, Semnan University

Filippo de Monte |
Department of Industrial and Information Engineering and Economics, University of L'Aquila


نشانی اینترنتی http://jcarme.sru.ac.ir/article_874_7105d03d85955a3895f98bf8fa89e70d.pdf
فایل مقاله اشکال در دسترسی به فایل - ./files/site1/rds_journals/484/article-484-1716781.pdf
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات