Clinical applications of virtual, non-contrast head images derived from dual-source, dual-energy cerebrovascular computed tomography angiography
چکیده انگلیسی مقاله
Background: This study set out to evaluate the utility of cerebrovascular virtual non-contrast (VNC) scans. Materials and Methods: Conventional non-contrast (CNC) and dual-energy computed tomography angiography (DE-CTA) head scans were conducted on 100 subjects, of which 46 were normal, 15 had parenchymal hematomas of the brain, 13 had ischemic infarction, 22 had tumors, and 4 had calcified lesions. VNC images were extracted from the DE-CTA head scans by post-processing. The true (or conventional) and VNC images were compared in terms of the mean CT attenuation value and signal-to-noise ratio (SNR) of the cerebral parenchyma, the image quality, the lesion detection sensitivity, and the radiation exposure level. Results: The image qualities of the CNC and VNC scans were (4.95 ± 0.22) points and (3.94 ± 0.24) points (t = 31.18, P < 0.05), the mean CT values for the CNC and VNC images were (34.6 ± 2.44) and (28.6 ± 5.40) HU (t = 10.126, P < 0.05), the SNRs were (9.45 ± 1.26) and (6.87 ± 1.77), and the HU for white matter was (t = 11.859, P< 0.05), respectively. The effective radiation doses from the DE-CTA head scans and the conventional non-contrast scans were (8.55 ± 0.57) mSv and (9.41 ± 1.00) mSv, respectively. No significant difference in the lesion detection sensitivities was observed between the CNC and VNC scans, except for tiny calcified lesions, which could not be identified by a VNC scan. Conclusion: VNC and contrast-enhanced images could be obtained from DE-CTA head scans and could aid in the diagnosis of cerebral lesions. The radiation dose from the VNC scan was less than that from the CNC scan.
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
d هانیه | d. han
medical imaging center, the first hospital affiliated kunming medical college, kunming, 650032, china
x j xie | x j xie
medical imaging center, the first hospital affiliated kunming medical college, kunming, 650032, china
l wen | l. wen
medical imaging center, the first hospital affiliated kunming medical college, kunming, 650032, china
نشانی اینترنتی
http://www.ijrr.com/browse.php?a_code=A-10-1-614&slc_lang=en&sid=en
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
Radiation Biology
نوع مقاله منتشر شده
مطالعه موردی
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات