عنوان انگلیسی A quality assurance program for an amorphous silicon electronic portal imaging device using in-house developed phantoms: a method development for dosimetry purposes
چکیده انگلیسی مقاله Background: Electronic portal imaging devices (EPIDs) play an important role in radiation therapy portal imaging, geometric and dosimetric verifications. A successful utilization of EPIDs for imaging and dosimetric purposes requires a reliable quality control process routine to be carried out regularly. In this study, two in-house phantoms were developed and analyzed for implementation in a quality assurance program for dosimetry purposes. Materials and Methods: An amorphous silicon (a-Si) imager (OptiVue500) was used. A low contrast resolution phantom and an image quality phantom were constructed and implemented. Low contrast resolution of the EPID was evaluated by counting the number of holes detectable in the image of phantom using human observers and a software. The image quality phantom was used for modulation transfer function, contrast to noise ratio and noise level evaluations. This phantom contains five sets of high-contrast rectangular bar patterns of variable spatial frequencies and six uniform regions. Results: Although the manual low contrast resolution method was observer-dependent and insensitive to artifacts, the automatic method was robust and fully objective but sensitive to artifacts. The critical frequency values for 6 and 18 MV were 0.3558±0.006 lp/mm and 0.2707±0.006 lp/mm respectively. The contrast-to-noise ratio was found to be ~ 240% higher for 6 MV compared to 18 MV. Conclusion: The developed phantoms provide a convenient process for periodic performance of an EPID. These phantoms are independent of the EPID system and provide robust tools for continuous monitoring of image quality parameters as well as dosimetric parameters.
کلیدواژه‌های انگلیسی مقاله Electronic portal imaging device, quality assurance, phantom

نویسندگان مقاله a جمعه زاده | a. jomehzadeh
medical physics department, isfahan university of medical sciences, isfahan, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی اصفهان (Isfahan university of medical sciences)

p شکرانی | p. shokrani
medical physics department, isfahan university of medical sciences, isfahan, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی اصفهان (Isfahan university of medical sciences)

m محمدی | m. mohammadi
medical physics department, hamadan university of medical sciences, hamadan, iran

سازمان اصلی تایید شده: دانشگاه علوم پزشکی همدان (Hamadan university of medical sciences)

a عموحیدری | a. amouheidari
radiation oncology department, isfahan milad hospital, isfahan, iran



نشانی اینترنتی http://www.ijrr.com/browse.php?a_code=A-10-1-514&slc_lang=en&sid=en
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده فیزیک پزشکی
نوع مقاله منتشر شده تحقیق بدیع
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات