این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
International Journal of Radiation Research، جلد ۱۲، شماره ۲، صفحات ۱۳۹-۱۴۹

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی An investigation into the potential applicability of gel dosimeters for dosimetry in boron neutron capture therapy
چکیده انگلیسی مقاله Background: The aim of this work was to establish how well gel dosimeters performed, as substitutes for brain tissue compared with standard phantom materials such as water, polymethyl-methacrylate (or PMMA), A150 plastic and TE- liquid phantom material for dosimetry of neutron beams in boron neutron capture therapy. Materials and Methods: Thermal neutron fluence, photon dose and epithermal neutron dose distributions were computed for the epithermal neutron beam of the optimized linac based BNCT. Results: Amongst all investigated phantom materials, TE-liquid was shown to be a better substitute for brain tissue than other phantom materials. The differences between TE- liquid and brain at the depth of 6.1 cm for thermal neutron fluence, gamma dose and epithermal neutron dose distributions was calculated 2.80%, 2.40% and -13.87% , respectively. In comparison with the other gel dosimeters, LMD2 provided a better simulation of radiation transport in the brain. It's results differed from the real brain, at the depth of 6.1 cm, for thermal neutron fluence, gamma dose and epithermal neutron dose distributions, by -1.27%, 4.20% and 21.05% respectively. Conclusion: Even though, in gamma dose distribution the LMD2 has large deviation from brain tissue distribution, the deviation is approximately independent of depth, so the results can be multiplied by a constant coefficient to be more consistent with reality. Even though, TE- liquid showed satisfactory results for brain tissue substitution in BNCT, but some properties of gel dosimeters such as three dimensionality, make LMD2 a potentially good dosimeter for dosimetric verification in BNCT.
کلیدواژه‌های انگلیسی مقاله Gel dosimetry, BNCT, phantom, MCNP, dose distribution

نویسندگان مقاله سید محمد ابطحی | s m abtahi
university of shahid beheshti, radiation medicine department, p. o. box 19839- 63113, tehran, iran

سازمان اصلی تایید شده: دانشگاه شهید بهشتی (Shahid beheshti university)

سید محمدرضا آقامیری | s m r aghamiri
university of shahid beheshti, radiation medicine department, p. o. box 19839- 63113, tehran, iran

سازمان اصلی تایید شده: دانشگاه شهید بهشتی (Shahid beheshti university)

h خلفی | h khalafi
nuclear science and technology research institute nstri , tehran, iran


f رحمانی | f. rahmani
university of shahid beheshti, radiation medicine department, p. o. box 19839- 63113, tehran, iran

سازمان اصلی تایید شده: دانشگاه شهید بهشتی (Shahid beheshti university)


نشانی اینترنتی http://www.ijrr.com/browse.php?a_code=A-10-1-499&slc_lang=en&sid=en
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده Radiation Biology
نوع مقاله منتشر شده تحقیق بدیع
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات