این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
سه شنبه 18 آذر 1404
International Journal of Radiation Research
، جلد ۱۱، شماره ۴، صفحات ۲۱۵-۲۲۴
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Small photon field dosimetry using EBT2 Gafchromic film and Monte Carlo simulation
چکیده انگلیسی مقاله
Background: Small photon fields are increasingly used in modern radiotherapy especially in intensity modulated radiation therapy (IMRT) and stereotactic radiosurgery (SRS) treatments. Accurate beam profile and central axis depth doses measurements of such beams are complicated due to the electron disequilibrium. Hence the EBT2 (external beam therapy) Gafchromic film was used for dosimetry of small circular photon beams because of its high spatial resolution. The results of EBT2 film were compared with PinPoint measurements and Monte Carlo calculations. Materials and Methods: Four small field sizes (5, 10, 20 and 30 mm diameters) were produced by circular cones coupled to a Varian Clinac-2100 linear accelerator at 6MV photon beam energy. Experimental measurements were carried out using two dosimeters: The Gafchromic EBT2 film and the 0.015 cm3 PinPoint ionization chamber (PTW, type 31006). The EGSnrc/BEAMnrc code was used to calculate dosimetric parameters for the above small fields. Results: The results showed that the PDD values measured by EBT2 film had maximum local differences 4% and 3% with PinPoint measurements and MC calculations respectively. The measurements of penumbra (80-20%) at 5 cm depth in a water phantom and SSD=100 cm by EBT2 film were up to 0.8 and 0.4 mm smaller than PinPoint measurements and MC calculation respectively. Our results show good agreement between EBT2 film measurements and MC calculation for small field output factors but PinPoint measurements need correction factors. Conclusion: This study showed that the Gafchromic EBT2 film is suitable detector for small field dosimetry especially for penumbra and output factor measurements.
کلیدواژههای انگلیسی مقاله
Small field, dosimetry, Gafchromic EBT2 film, Monte Carlo
نویسندگان مقاله
m یاراحمدی | m. yarahmadi
kurdistan university of medical sciences, sanandaj, iran
حسینعلی ندایی | h a nedaie
department of medical physics , faculty of medicine, tehran university of medical sciences, tehran, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی تهران (Tehran university of medical sciences)
m اله وردی | m. allahverdi
department of medical physics , faculty of medicine, tehran university of medical sciences, tehran, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی تهران (Tehran university of medical sciences)
kh اثنی عشری | kh. asnaashari
department of radiotherapy , cancer institute, tehran university of medical sciences, tehran, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی تهران (Tehran university of medical sciences)
امید علی sauer | o a sauer
klinik und poliklinik für strahlentherapie, university of würzburg, josef-schneider-strasse 11, 97080 würzburg, germany
نشانی اینترنتی
http://www.ijrr.com/browse.php?a_code=A-10-1-476&slc_lang=en&sid=en
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
فیزیک پزشکی
نوع مقاله منتشر شده
تحقیق بدیع
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات