این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
International Journal of Radiation Research، جلد ۱۱، شماره ۳، صفحات ۱۸۹-۱۹۳

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Calibration of iridium-192 source by ionization chamber for high dose rate brachytherapy
چکیده انگلیسی مقاله Background: The effectiveness and safety of brachytherapy treatment is mainly concerned with the calibration of sources and their traceability to internationally accepted Standards. Secondary Standard Dosimetry Laboratory (SSDL) does not offer calibration of ionization chambers with gamma-ray spectrum of high dose rate source 192Ir . This work has been carried out to calibrate the high dose rate (HDR) 192Ir sources. Materials and Methods: An interpolation procedure, using calibrations above 1.25 MeV (60Co), and below 135 kV X-rays (61.1 keV), the exposure-weighted average energy 397 keV of 192Ir is employed. Using Farmer ionization chamber HDR 192Ir source has been calibrated by free in-air measurement technique and then the calibrated source has been used to calibrate well-type ionization chamber. Results: Difference between in-air measurement and that of manufacturer’s remained within ± 3%, and the difference between in-air measurement and well-type chamber remained within ± 1%. Comparison between well-type measurements and manufacturer values shows differences less than ± 2%. All these differences are within the acceptable tolerance limits. Conclusion: The method presented shows good degree of accuracy so that the traceability of calibration is assured. Installation of a new brachytherapy source needs to be calibrated by in-air measurement technique and then this calibrated source should be used for well chamber calibration. Brachytherapy community is suggested to calibrate their sources with this method.
کلیدواژه‌های انگلیسی مقاله Brachytherapy, calibration, ionization chamber, HDR.

نویسندگان مقاله محمدعلی gadhi | m a gadhi
bahawalpur institute of nuclear medicine and oncology bino bahawalpur, pakistan


سید علی buzdar | s a buzdar
department of physics, the islamia university of bahawalpur, pakistan


m افضل | m. afzal
department of physics, the islamia university of bahawalpur, pakistan


sh fatmi | sh. fatmi
bahawalpur institute of nuclear medicine and oncology bino bahawalpur, pakistan


محمدصادق اختر | m s akhtar
bahawalpur institute of nuclear medicine and oncology bino bahawalpur, pakistan


امیرحسین nizamani | a h nizamani
department of physics, university of sind, jamshoro, hyderabad, pakistan



نشانی اینترنتی http://www.ijrr.com/browse.php?a_code=A-10-1-471&slc_lang=en&sid=en
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده Nuclear Medicine
نوع مقاله منتشر شده مرور و بررسی کلی
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات