Patient doses from X-ray computed tomography examinations by a single-array detector unit: Axial versus spiral mode
چکیده انگلیسی مقاله
Background: X-ray computed tomography (CT) examinations deliver a significant amount of radiation doses to patients comparing to conventional radiography examinations. The objective of the current study was to analyze and investigate the average patient received dose from axial and spiral CT exams in a medical imaging center. Material and Methods: In this study, the patient imaging technique, weight and height were recorded. The patients’ doses provided by CT unit in terms of CTDIw were also recorded. Then, other dosimetric quantities including dose-length product (DLP) and effective dose were calculated for each patient using the recorded data. The average values were obtained for all the studied dosimetric quantities. Also, their distribution in terms of examined regions and imaging mode ie, axial and spiral CT were analyzed by SPSS software. Results: For all patients, the mean effective dose of 4.4 mGy with the standard deviation of 9.2 was found. The CTDIw for axial group was two times higher than spiral ones. Conversely, the effective dose of axial group was less than spiral group. Additionally, the effective doses of 2.3 and 5.2 mSv were found for axial and spiral, receptively. For both quantities of CTDIw and effective dose, the observed difference between axial and spiral modes were significant (P< 0.001). Conclusion: Our results showed that although the patient doses in the current study was comparable with the reported values by similar studies in other countries, it was higher than the reported values of a similar study in Iran. Exposure technique’s optimaization and further review in routine CT examinations were recommended. Iran. J. Radiat. Res., 2012 10(2): 89‐94
کلیدواژههای انگلیسی مقاله
X-ray CT dose, patient effective dose, spiral CT, DLP, CTDIw
نویسندگان مقاله
سید محمد قوامی | s m ghavami
radiology department, paramedical school, tabriz university of medical sciences, tabriz, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی تبریز (Tabriz university of medical sciences)
a مصباحی | a. mesbahi
medical physics department, medical school, tabriz university of medical sciences, tabriz, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی تبریز (Tabriz university of medical sciences)
i پسیانیان | i. pesianian
radiology department, paramedical school, tabriz university of medical sciences, tabriz, iran
سازمان اصلی تایید شده
: دانشگاه علوم پزشکی تبریز (Tabriz university of medical sciences)
نشانی اینترنتی
http://www.ijrr.com/browse.php?a_code=A-10-1-426&slc_lang=en&sid=en
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
Radiation Biology
نوع مقاله منتشر شده
تحقیق بدیع
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات