این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
International Journal of Radiation Research، جلد ۹، شماره ۳، صفحات ۱۵۹-۱۶۶

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Evaluation of depth dose characteristics of superficial X-rays machine using different kVp and applicators diameter
چکیده انگلیسی مقاله Background: Radiotherapy Treatment Planning requires different dosimetric quantities as input in order to calculate a desired dose distribution. This study has been focused to evaluate the depth dose characteristics of superficial X-rays being used for radiotherapy treatment. Materials and Methods: Computerized 3-D water phantom of multi-data system was used. The measurements were made through PTW (Physikalirsch-Technische Werkstalten) farmer type NT-30006 waterproof ionization chamber of 0.6cc, and PTW electrometer for digital dose rate reading in Gy/min using five different diameter applicators and filters at five different values of accelerating potentials (kVps). Results: The dose rate at various kVp X-ray beams was observed to decrease significantly with increasing depth in water phantom for all applicator diameters from 98% (at 0.1cm depth) down to 43% (at 2cm i.e. reference condition). The dose rate increases by increasing the value of kVp with a maximum at 150 kVp (1.6 and 0.93 Gy/ min for respective applicator diameters 2.5cm and 10cm). Applicator with 2.5cm diameter demonstrates better dose rate at 85kVp at different depths. PDD decreases lower than 50% for all combination of applicators and kVps at/or above 2cm depth so these measurements should not be considered for treatment planning. Conclusion: Higher energy X-rays are suggested to be used for applicators of higher diameters and smaller energy X-rays for applicators having smaller diameters. Iran. J. Radiat. Res., 2011 9(3): 159-166
کلیدواژه‌های انگلیسی مقاله

نویسندگان مقاله m اسماعیل | m. ismail
department of physics, the islamia university of bahawalpur, bahawalpur, pakistan


m افضل | m. afzal
department of physics, the islamia university of bahawalpur, bahawalpur, pakistan


m ندیم | m. nadeem
bahawalpur institute of nuclear medicine and oncology bino , bahawalpur, pakistan


علی محمد رعنا | a m rana
department of physics, bahauddin zakariya university, multan, pakistan


s امجد | s. amjad
department of physics, the islamia university of bahawalpur, bahawalpur, pakistan


سید علی buzdar | s a buzdar
department of physics, the islamia university of bahawalpur, bahawalpur, pakistan



نشانی اینترنتی http://www.ijrr.com/browse.php?a_code=A-10-1-397&slc_lang=en&sid=en
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده Radiation Biology
نوع مقاله منتشر شده تحقیق بدیع
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات