این سایت در حال حاضر پشتیبانی نمی شود و امکان دارد داده های نشریات بروز نباشند
صفحه اصلی
درباره پایگاه
فهرست سامانه ها
الزامات سامانه ها
فهرست سازمانی
تماس با ما
JCR 2016
جستجوی مقالات
سه شنبه 18 آذر 1404
International Journal of Radiation Research
، جلد ۸، شماره ۲، صفحات ۶۱-۷۴
عنوان فارسی
چکیده فارسی مقاله
کلیدواژههای فارسی مقاله
عنوان انگلیسی
Dosimetry limitations and pre-treatment dose profile correction for sliding window IMRT
چکیده انگلیسی مقاله
Background: This work investigated the dosimetry limitations of the random and systematic uncertainties of sliding window (SW) intensity modulated radiation therapy (IMRT). Materials and Methods: A Varian 21EX linear accelerator, Pinnacle3 treatment planning system and radiographic film dosimetry was used. The limitations of the SW were studied using beam modulation ranging from 2 to 100 MU/beam, DR from 100 to 600 MU min-1, LV from 1 to 5 cm s-1 and field size up to 12 × 12 cm2. The random and systematic errors were investigated using clinical and flat beams, as well as beams of high profile modulation including linear, exponential, and sinusoidal profiles. Results: The leading edge and plateau of the SW profiles have a significant deformation for higher DR and for beams of < 10 MUs/beam. It was found that the error is directly proportional to the DR and LV, and inversely proportional to the number of MU/beam. Conclusion: The high DR and LV are limiting factors, producing random profile deformation when SW beams of small number of MU/beam are delivered. A very good agreement was found between the planned and delivered geometrical and clinical dose profiles when beams > 10 MUs irradiated by a DR from 100 to 600 MU min-1 and LV from 1 to 5 cm s-1. After the proposed correction, an average difference < 0.5% for clinical profiles was measured for beams irradiated with DR = 600 MU min-1 and LV= 5 cm s-1. It was concluded that this correction methodology may serve as a pre-treatment Quality Assurance tool for SW IMRT beams. Iran. J. Radiat. Res., 2010 8 (2): 61-74
کلیدواژههای انگلیسی مقاله
نویسندگان مقاله
g grigorov | g. grigorov
grand river regional cancer center, grand river hospital, p.o. box 9056, 835 king street west, kitchener, on, canada n2g 1g3
j c l chow | j c l chow
radiation medicine program, princess margaret hospital, 610 university avenue, toronto, on, canada m5g 2m9
n یزدانی | n. yazdani
grand river regional cancer center, grand river hospital, p.o. box 9056, 835 king street west, kitchener, on, canada n2g 1g3
نشانی اینترنتی
http://www.ijrr.com/browse.php?a_code=A-10-1-353&slc_lang=en&sid=en
فایل مقاله
فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده
en
موضوعات مقاله منتشر شده
Radiation Biology
نوع مقاله منتشر شده
تحقیق بدیع
برگشت به:
صفحه اول پایگاه
|
نسخه مرتبط
|
نشریه مرتبط
|
فهرست نشریات